Biomechanical Evaluation of Primary Stiffness of Tibiotalar Arthrodesis with an Intramedullary Compression Nail and Four Other Fixation Devices

Author:

Mueckley Thomas Martin12,Eichorn Stefan13,Oldenburg Geert von14,Speitling Andreas14,DiCicco Joseph D.15,Hofmann Gunther O.12,Bühren Volker16

Affiliation:

1. Munich, Germany

2. Department of Trauma, Hand, and Reconstructive Surgery, University Hospital Jena, Jena, Germany

3. Department of Biomechanics, Technical University Munich, Munich, Germany

4. Stryker Trauma, Schönkirchen/Kiel, Germany

5. Grandview Hospital, Dayton, Ohio

6. Berufsgenassenschaftliche Unfallklinik Murnau, Küntscherstr. 8 D-82418 Murnau, Germany

Abstract

Background: Many techniques of tibiotalar arthrodesis have been described. Screw fixation is widely used. At our center, intramedullary compression nailing has been successfully used for over 10 years. The question to be answered by this study was whether tibiotalar arthrodesis with a compressed intramedullary nail was superior, in terms of primary stiffness and fusion-site compression, to selected other techniques. Methods: Plane fusion surfaces were machined in third-generation synthetic composite tibiae and the bodies of anatomically correct tali; fixation was with a compressed external fixator (cEF), an uncompressed interlocking nail (uIN), a compressed interlocking nail (cIN), and two different three-screw techniques (ST1 and ST2); three specimens per construct were tested. The compressed contact surface of each construct was measured with pressure-sensitive film and expressed as a percent of the available fusion-site area. Construct stiffness was tested in dorsiflexion/plantar flexion (D/P), varus/valgus (V/V), and internal rotation/external rotation (I/E), analyzing 20 cycles per loading mode. Results: Compressed surface area: cIN 80% ± 10.7; cEF 60% ± 8.6; ST2 59% ± 4.4; ST1 55% ± 6.1; uIN no discernible compression. The greatest primary stiffness in D/P was obtained with the cIN ( p < 0.001), followed by ST1. In V/V, ST1 and the cIN had the greatest primary stiffness; the two techniques did not differ significantly. Stabilization with the cEF was significantly better ( p < 0.001) than with ST2. In I/E, the cIN produced the greatest primary stiffness ( p < 0.001), followed by the two screw techniques, which did not differ significantly between themselves. The uIN had the least primary stiffness in all directions tested. Conclusions: In this biomechanical study, the cIN and ST1 were superior, in terms of primary stiffness in tibiotalar arthrodesis, to the other techniques tested. In D/P and I/E, the cIN construct was signficantly stiffer than the ST1 construct, whose I/E rigidity might, however, be enhanced by a fourth, horizontal screw. Clinical Relevance: Intramedullary compression nailing offers stable tibiotalar arthrodesis fixation with a large bony contact area and may enhance the likelihood of successful tibiotalar arthrodesis.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3