Abstract

Background: Several different techniques have been used for fixation of first metatarsocuneiform (MTC) joint arthrodesis, a standard treatment for arthritis, instability, and deformity of the MTC joint. Improved plating systems using locking designs are now available, but no studies have yet compared this construct with other methods. We compared load to failure with a locking plate design versus standard crossed-screw fixation. Methods: Ten matched pairs of fresh frozen cadaver feet were used. The bone density of each pair was measured with DEXA scanning. One foot of each pair was randomly assigned to have a dorsomedial Normed H titanium locking plate (Normed Medizin-Technik Vertriebs-GmbH, D-78501 Tuttlingen, Germany) applied to the first MTC joint. On the other foot of the pair, fixation of the first MTC joint was done with crossed ACE DePuy 4.0 (DePuy/Ace, Warsaw, IN) titanium cannulated screws. The first metatarsal and first cuneiform were then isolated and planted in an epoxy resin. The specimens were loaded to failure in a four-point bending configuration using a MTS Mini Bionix test frame (MTS Systems Corp., Eden Prairie, MN). Failure was defined as displacement of more than 3 mm at the arthrodesis site. The Student t-test was used to determine any observed differences, with significance set at p ≤ 0.05. Results: The mean maximal load to failure was 140.08 N (SD ± 77.1) for screw fixation alone and 58.09 N (SD ± 11.86) for the H-locking plate. This difference was statistically significant ( p = 0.008). The mean stiffness of the construct for screw fixation alone was 83.10 N/mm (SD ± 49.8) and 19.96 N/mm for the H-locking plate. This difference also was statistically significant ( p = 0. 004). Conclusion: Screw fixation for first MTC arthrodesis created a stronger and stiffer construct than did the H-locking plate. This was likely due to the mechanical design of the implants. Compression across the MTC joint could be applied with the screws, but the plate relied on a fixed angle design with no compression.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3