Short-Term Complications, Reoperations, and Radiographic Outcomes of a New Fixed-Bearing Total Ankle Arthroplasty

Author:

Saito Guilherme H.1ORCID,Sanders Austin E.1,de Cesar Netto Cesar1ORCID,O’Malley Martin J.1,Ellis Scott J.1,Demetracopoulos Constantine A.1

Affiliation:

1. Foot and Ankle Service, Department of Orthopaedic Surgery; Hospital for Special Surgery, New York, NY 10021, USA

Abstract

Background: With the increasing use of total ankle arthroplasty (TAA), new implants with varied configurations are being developed every year. This study aimed to assess the early complications, reoperations, and radiographic and clinical outcomes of the Infinity TAA. To date, clinical results of this novel implant have not been published. Methods: A retrospective analysis of 64 consecutive ankles that underwent a primary Infinity TAA from July 2014 to April 2016 was performed. Patients had an average follow-up of 24.5 (range, 18-39) months. Medical records were reviewed to determine the incidence of complications, reoperations, and revisions. Radiographic outcomes included preoperative and postoperative tibiotalar alignment, tibial implant positioning, the presence of periprosthetic radiolucency and cysts, and evidence of subsidence or loosening. Additionally, patient-reported outcomes were analyzed with the Foot and Ankle Outcome Score (FAOS). Results: Survivorship of the implant was 95.3%. Fourteen ankles (21.8%) presented a total of 17 complications. A total of 12 reoperations were necessary in 11 ankles (17.1%). Revision surgery was indicated for 3 ankles (4.7%) as a result of subsidence of the implant. Tibiotalar coronal deformity was significantly improved after surgery ( P < .0001) and maintained during latest follow-up ( P = .81). Periprosthetic radiolucent lines were observed around the tibial component in 20 ankles (31%) and around the talar component in 2 ankles (3.1%). A tibial cyst was observed in 1 ankle (1.5%). Outcome scores were significantly improved for all FAOS components analyzed ( P < .0001), from 39.0 to 83.3 for pain, from 34.0 to 65.2 for symptoms, from 52.3 to 87.5 for activities of daily living, and from 15.7 to 64.2 for quality of life. Conclusion: Most complications observed in the study were minor and successfully treated with a single reoperation procedure or nonoperatively. Failures and radiographic abnormalities were most commonly related to the tibial implant. Further studies with longer follow-up are needed to evaluate the survivorship of the tibial implant in the long term. Level of evidence: Level IV, retrospective case series.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 43 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3