Implant Choice May Reduce the Risk of Early Mechanical Failure in Total Ankle Replacement

Author:

Henry Jensen K.1ORCID,Shaffrey Isabel2ORCID,Cororaton Agnes D.3ORCID,Munita Joaquin Palma1ORCID,Cody Elizabeth1ORCID,O’Malley Martin1,Deland Jonathan1ORCID,Ellis Scott1,Demetracopoulos Constantine1ORCID

Affiliation:

1. Foot and Ankle Department, Hospital for Special Surgery, New York, NY

2. Duke University School of Medicine, Durham, North Carolina

3. Biostatistics Department, Hospital for Special Surgery, New York, NY

Abstract

Background: Total ankle replacements (TARs) have rapidly advanced in terms of volume, technique, design, and indications. However, TARs are still at risk for early mechanical failure and revision. Prior studies have investigated potential risk factors for failure, but have been limited to smaller series or older implants. This study sought to identify risk factors for early mechanical failure in modern TAR. Methods: This is a retrospective study of a single-institution registry. Five surgeons contributed cases involving patients who underwent a primary TAR with any implant. Implants were grouped on the basis of the type of fixation. The primary outcome was early mechanical failure (revision with component removal for a non-infectious etiology, that is, subsidence, aseptic loosening, and/or malalignment). Logistic regression determined the effects of age, weight, hindfoot arthrodesis, implant type, and radiographic deformity on failure. Results: The 731 included patients had a mean follow-up of 2.7 years. Ten percent (71 patients) had hindfoot arthrodesis. There were 33 mechanical failures (4.5%) at a mean of 1.7 years after the index surgical procedure. Our model demonstrated that hindfoot arthrodesis was associated with 2.7 times greater odds of failure (p = 0.045), every 10 kg of body weight increased the odds of tibial-sided failure by 1.29 times (p = 0.039), and implants with more extensive tibial fixation (stems or keels) lowered the odds of tibial failure by 95% (p = 0.031). Conclusions: In patients with uncontrollable risk factors (hindfoot arthrodesis) or risk factors that may or may not be modifiable by the patient (weight), implants with more robust tibial fixation may be able to reduce the risk of early mechanical failure. Further research is warranted to support efforts to decrease early failure in TAR. Level of Evidence: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3