Abstract

Background: Arthritis of the metatarsophalangeal (MTP) joint is characterized by loss of MTP joint range of motion (ROM) and pain. Joint arthroplasty is one treatment option, and while results can be satisfactory, there is still room for improvement. The aim was to use cadaveric model to compare the sagittal kinematics and articulating contact properties of 4 different first metatarsal head designs of an MTP joint implant. Methods: Six cadaveric feet were each prepared with a single modular first MTP joint total arthroplasty. A standard cyclic load, which induced hallux dorsiflexion, was applied and motion measured from high resolution images. Contact behavior was collected simultaneously using a pressure transducer. Data collected compared the native joint with 4 different reconstructed cases. Each reconstructed joint used a different metatarsal-head-component while reusing the same phalangeal component to compare the 4 alternative metatarsal head designs. Results: All reconstructed joints displayed greater ROM compared with the intact joint. Of the 4 metatarsal head components, the grooved, anatomical design demonstrated the greatest dorsiflexion when compared to the standard design, 31.6 degrees (SD ± 8.6 degrees), P < .05. All reconstructed joints displayed contact areas lower than the intact (~50%, P < .001). The grooved metatarsal-head-component experienced the least contact force ( P < .015), and the eccentric component underwent the greatest contact pressure ( P < .05) when compared to the intact case. Conclusions: In this study of a first metatarsophalangeal joint replacement design, ROM was shown to be better for the more anatomically designed metatarsal head, while contact properties did not vary across different designs. Clinical Relevance: This information may be useful in the development of new metatarsal components.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 16 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3