Clinical and MRI Donor Site Outcomes Following Autologous Osteochondral Transplantation for Talar Osteochondral Lesions

Author:

Fraser Ethan J.1,Savage-Elliott Ian1,Yasui Youichi12,Ackermann Jakob1,Watson Geoffrey1,Ross Keir A.1,Deyer Timothy3,Kennedy John G.1

Affiliation:

1. Hospital for Special Surgery, New York, NY, USA

2. Teikyo University School of Medicine, Department of Orthopaedic Surgery, Tokyo, Japan

3. East River Medical Imaging, New York, NY, USA

Abstract

Background: Autologous osteochondral transplantation (AOT) has an inherent risk of donor site morbidity (DSM). The reported rates of DSM vary from 0% to 50%, with few studies reporting clinical or imaging outcomes at the donor site as a primary outcome and even fewer report these outcomes when a biosynthetic plug backfill is employed. Although TruFit (Smith & Nephew, Andover, MA) plugs have been removed from the market for regulatory purposes, biphasic plugs (including TruFit plugs) have been used for several years and the evaluation of these is therefore pertinent. Methods: Thirty-nine patients who underwent forty AOT procedures of the talus, with the donor graft being taken from the ipsilateral knee, were included. Postoperative magnetic resonance imaging (MRI) was used to assess the donor site graded with magnetic resonance observation of cartilage repair tissue (MOCART) scoring. Lysholm scores were collected preoperatively, at the time of magnetic resonance imaging (MRI), and again at 24 months and at final follow-up to assess clinical outcomes. Statistical analysis was performed to establish if there was any correlation between MRI assessment of the donor site and clinical outcomes. The mean patient age was 36.2 ± 15.7 years with a mean follow-up of 41.8 ± 16.7 months. Results: All patient donor site defects were filled with OBI TruFit biphasic plugs. DSM was encountered in 12.5% of the patient cohort at 24 months, and in these patients, the Lysholm score was a mean 87.2 ± 5.0. At final follow-up, DSM was reduced to 5%. Lysholm scores for the entire cohort were 98.4 ± 4.6 and 99.4 ± 3.1 at 24 months and final follow-up, respectively. MRI of the donor sites were taken at an average of 18.1 ± 13.5 (range, 3-48) months postoperatively and the mean MOCART score was 60.0 ± 13.5. No correlation was found between the MOCART score and Lysholm outcomes at the donor knee ( P = .43, r = 0.13). Conclusion: Low incidence of DSM and good functional outcomes were achieved with AOT. Additionally, MRI findings did not predict clinical outcomes in our study. Level of Evidence: Level IV, retrospective case series.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3