A Determination of Ankle Kinematics Using Fluoroscopy

Author:

Komistek Richard D.12,Stiehl James B.1,Buechel Frederick F.2,Northcut Eric J.2,Hajner Mary E.2

Affiliation:

1. Rocky Mountain Musculoskeletal Research Laboratory, 2425 South Colorado Blvd., Denver, Colorado 80222.

2. Colorado School of Mines, 1500 Illinois, Golden, Colorado 80401.

Abstract

In vivo weight-bearing studies utilizing dynamic video fluoroscopy have been shown to offer an accurate and reproducible method for determining the kinematics of a joint. The purpose of this study was to evaluate translational and rotational motions of the distal tibia relative to the talus in the sagittal and frontal planes. Ten subjects, each having a normal ankle and a total ankle arthroplasty on the opposite side (Buechel-Pappas Total Ankle, Endotec, South Orange, NJ), were studied under in vivo, weight-bearing conditions using video fluoroscopy. All ten subjects were judged to have a successful arthroplasty without demonstrable pain or ligament instability. Under weight-bearing conditions, each subject performed successive motions moving from maximum dorsiflexion to plantarflexion. At maximum dorsiflexion, both the normal and implanted ankles had similar sagittal midline talar contact positions but with plantar flexion, implanted ankles had increased posterior talar contact. Contact points on the distal tibia revealed that the lateral surface contacted at the midline or posterior throughout range-of-motion with minimal translation. The medial distal tibia contacted the talus posterior on plantarflexion and often moved anteriorly with dorsiflexion. This translation described relative external rotation of the distal tibia on plantar flexion and internal rotation on dorsiflexion. The measured distances were larger for the implanted ankles with higher variability. The average range-of-motion was 37.4° for normal ankles and 32.3° for implanted ankles. This study defines the normal kinematic rotational and translational motions of the ankle joint by accurately describing the three dimensional joint orientations. The implanted ankles experienced rotational and translational motions but had contacts more posterior, possibly related to surgical technique or alterations of ligamentous tension.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 64 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3