Kinematics of a Total Arthroplasty of the Ankle: Comparison to Normal Ankle Motion

Author:

Michelson James D.1,Schmidt Guy R.1,Mizel Mark S.1

Affiliation:

1. Baltimore, Maryland

Abstract

Although the concept of a total ankle arthroplasty has been advanced as a method for treating severe ankle arthritis, the clinical experience with all of the models developed has been discouraging. Both the constrained designs, which maximize joint contact area by restricting the available motion, and the unconstrained designs, which allow more normal motion at the expense of higher contact stresses, uniformly result in implant loosening, pain, and clinical failure in 2 to 7 years. This has led to the recommendation against the use of a total ankle arthroplasty except in very low-demand patients. Failure of ankle implants can be ascribed to either anatomic considerations (e.g. -the talus is too small to accommodate the stress transfers of a prosthesis), or mechanical etiologies. Abnormal 3-dimensional motion of the ankle following arthroplasty would fall into the latter category. This study examined the motion that occurs after implantation of an unconstrained-type total ankle arthroplasty. Using previously validated methodology, axially loaded ankle specimens were cycled through an arc of plantarflex/dorsiflexion while measuring the resulting coupled internal/external and varus/valgus rotations. The average coupled motions in prosthetic ankles were not significantly different than their intact controls. There was, however, a significantly increased amount of hysteresis (defined as the difference between the upper and lower pathways of coupled motion at any given sagittal position) that occurred as the ankle was dorsiflexed and plantar flexed. The increased hysteresis was seen in both the axial and coronal planes. This indicates that there was a greater permitted envelop of motion in the prosthetic ankles compared to normal ankles. It is hypothesized that this subtle change in ankle kinematics caused by the arthroplasty leads to abnormal stress transfer at the prosthesis-bone interface, thereby promoting early implant failure.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 46 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3