A Biomechanical Comparative Analysis of Two Techniques for Tibiotalar Arthrodesis

Author:

Friedman Robert L.1,Glisson Richard R.2,Nunley James A.3

Affiliation:

1. Senior Resident, Division of Orthopaedic Surgery, Duke Medical Center, Durham, North Carolina.

2. Research Analyst, Division of Orthopaedic Surgery, Duke Medical Center.

3. Professor, Division of Orthopaedic Surgery, 2919 Duke Medical Center, Durham, North Carolina 27710.

Abstract

Two commonly used techniques for tibiotalar fusion were quantitatively compared using instrumented testing of the strength of the construct. The tibiae and tali from 10 pairs of fresh-frozen cadaveric limbs were used. One joint of each pair was fused using two 6.5-mm crossed cancellous screws from proximal to distal while the contralateral joint was fused using two 6.5-mm parallel cancellous screws from distal to proximal. Each specimen was subjected to cantilever bending and torsional testing by servohydraulic actuators. The bending tests included plantarflexion, dorsiflexion, inversion, and eversion, and measured the load during deflection applied 10 cm distal to the fusion site. The rigidity was expressed as newtons per millimeter of deflection. The torsional tests measured construct stiffness in external and internal rotation, and were expressed as newton-meters per degree of rotation. For the bending tests, the crossed screw construct was more rigid in eversion (23.1 N/mm, P = .0004) and dorsiflexion (16.9 N/mm, P = .02), while the parallel screw construct was more rigid in inversion (22.8 N/mm, P = .02) and plantarflexion (22.3 N/mm, P = .0007). In torsional testing, the crossed screw construct was at least 1.5 times stiffer than the parallel screw construct in resisting internal (1.7 N-m/deg versus 0.9 N-m/deg, P = .0001) and external (1.4 N-m/deg versus 0.9 N-m/deg, P = .02) rotation. In laboratory testing, the crossed screw technique is more rigid than the parallel screws, especially in resisting torsional stresses. Assuming that a stronger construct is desirable, and given that short leg casts commonly used after such fusions do not completely restrict torsional motion, this biomechanical analysis suggests that the crossed screw technique improves the likelihood of a successful arthrodesis.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 81 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3