Gas chromatography–mass spectrometric determination of bisphenol residues by dispersive solid phase extraction followed by activated carbon spheres cleanup from fish feed samples

Author:

Talari Kalpana12ORCID,Ganji Sai Krishna3,Tiruveedula Raja Rajeswari4ORCID

Affiliation:

1. Department of Chemistry, Acharya Nagarjuna University, Guntur, Andhra Pradesh, India

2. Department of Chemistry, Government College for Women (A), Guntur, Andhra Pradesh, India

3. Centre for Mass Spectrometry, Analytical and Structural Chemistry Division, CSIR-Indian Institute of Chemical Technology, Hyderabad, Telangana, India

4. Sri A.S.N.M. Government College (Autonomous), Palakol, Andhra Pradesh, India

Abstract

Bisphenols are known endocrine disruptors commonly utilized in food packaging and storage materials, which frequently come into touch with multiple food products packed in them. The bisphenols in fish feed and other feed materials for aquatic organisms are harmful. The consumption of such marine foods is hazardous. Hence, the feed of aquatic products needs to be verified for the presence of bisphenols. The present study was focused on developing and validating a rapid, selective, and sensitive method to quantify 11 bisphenols from the fish feed with dispersive solid-phase extraction, which was cleaned by an optimized amount of activated carbon spheres and silylated by N,O-bis(trimethylsilyl)trifluoro acetamide and analyzed by gas chromatography–mass spectrometry. The new method was rigorously tested and verified after carefully tuning various parameters affecting analyte recovery. Limit of detection (LOD) were set at 0.5–5 ng/g and limit of quantification (LOQ) at 1–10 ng/g, respectively, resulting in 95–114% recoveries. Interday and intraday precisions in terms of relative standard deviation were found to be less than 11%. The proposed approach was effectively applied in floating and sinking fish feeds. The obtained results showed that higher concentration of bisphenol A, followed by bisphenol TMC, and bisphenol M at a concentration of 256.10, 159.01, and 168.82 ng/g in floating feed and 88.04, 200.79, and 98.03 ng/g in sinking feed samples, respectively.

Publisher

SAGE Publications

Subject

Spectroscopy,Atomic and Molecular Physics, and Optics,General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3