Comparison of the Accuracy of Pedicle Screw Placement Using a Fluoroscopy-Assisted Free-Hand Technique with Robotic-Assisted Navigation Using an O-Arm or 3D C-Arm in Scoliosis Surgery

Author:

Li Chao1ORCID,Li Hao1ORCID,Su Junxiao1,Wang Zheng1ORCID,Li Donglai1,Tian Yonghao1,Yuan Suomao1,Wang Lianlei1,Liu Xinyu1ORCID

Affiliation:

1. Department of Orthopedics, Qilu Hospital of Shandong University, Jinan, Shandong, P. R. China

Abstract

Study Design Retrospective. Objectives To report and compare the application of robotic-assisted navigation with an O-arm or three-dimensional (3D) C-arm-assisted pedicle screw insertion in scoliosis surgery, and compare with free-hand technique. Methods One hundred and forty-four scoliosis patients were included in this study. Ninety-two patients underwent robotic-assisted pedicle screw insertion (Group A), and 52 patients underwent freehand fluoroscopy-guided pedicle screw insertion (Group B). Group A was further divided into Subgroup AI (n = 48; robotic-assisted navigation with an O-arm) and Subgroup AII (n = 44; robotic-assisted navigation with a 3D C-arm). The evaluated clinical outcomes were operation time, blood loss, radiation exposure, postoperative hospital stay, and postoperative complications. The clinical outcomes, coronal and sagittal scoliosis parameters and the accuracy of the pedicle screw placement were assessed. Results There were no significant differences in blood loss and postoperative hospital stay between Groups A and B ( P = .406, P = .138, respectively). Radiation exposure for patients in Group A (Subgroups AI or AII) was higher than that in Group B ( P < .005), and Subgroup AI had higher patient radiation exposure compared with Subgroup AII ( P < .005). The operation time in Subgroup AII was significantly longer than that in Subgroup AI and Group B ( P = .016, P = .032, respectively). The proportion of clinically acceptable screws was higher in Group A (Subgroups AI or AII) compared with Group B ( P < .005). Conclusions Robotic-assisted navigation with an O-arm or 3D C-arm effectively increased the accuracy and safety in scoliosis surgery. Compared with robotic-assisted navigation with a 3D C-arm, robotic-assisted navigation with an O-arm was more efficient intraoperatively.

Funder

National Nature Science Foundation

Shandong Natural Science Foundation

Publisher

SAGE Publications

Subject

Neurology (clinical),Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3