Nitinol Memory Rods Versus Titanium Rods: A Biomechanical Comparison of Posterior Spinal Instrumentation in a Synthetic Corpectomy Model

Author:

Massey Patrick A.1ORCID,Hoge Stephen1,Nelson Bradley G.1,Ogden Alan L.1,Mody Milan G.1,Myers Mitchell1,Bilderback Karl1,Solitro Giovanni1,Barton Richard S.1

Affiliation:

1. Louisiana State University Health, Shreveport, LA, USA

Abstract

Study Design: Biomechanical investigation. Objective: To compare the biomechanical performance of nitinol memory metal rods and titanium rods when used as posterior spinal instrumentation in a synthetic model. Methods: Biomechanical testing was performed using ultra-high-molecular-weight polyethylene blocks. Nineteen spinal constructs were created to allow comparison of 5.5-mm nitinol rods with 5.5-mm titanium rods. Static compression and rotational testing were performed on an Instron 8874 and Instron 4202 at 37°C to simulate body temperature. Results: The average titanium construct stiffness under static compression or bending was 47.2 ± 9.1 N/mm while nitinol’s stiffness averaged 48.9 ± 12.4 N/mm ( P = .83). During axial rotation testing, the nitinol rod system showed no torsional stiffness difference from the titanium system: 0.95 ± 0.03 Nm/deg versus 0.96 ± 0.17 Nm/deg, respectively ( P = 0.91). There was a statistically significant difference between the average torsional yield point for the titanium constructs (14.4 ± 1.6 Nm/deg) and nitinol constructs (21.3 ± 0.8 Nm/deg) ( P = .004). The torsional toughness of the nitinol constructs was also statistically greater than the titanium rods: 473 GN/m3 versus 784 GN/m3 ( P = .0006). There was no statistically significant difference between the nitinol group sustaining a higher number of fatigue cycles until failure and the titanium group (181 660 cycles vs 64 104 cycles, respectively, P = .22). Conclusions: This study provides biomechanical evidence that nitinol rods used in a posterior construct are comparable to titanium rods with regard to compression and have increased torsional failure load and torsional toughness. While nitinol trended toward superior fatigue resistance, there was no significant difference in nitinol versus titanium construct fatigue resistance.

Publisher

SAGE Publications

Subject

Clinical Neurology,Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司