Optimization of the Grashey View Radiograph for Critical Shoulder Angle Measurement: A Reliability Assessment With Zero Echo Time MRI

Author:

Yıldız Adalet Elçin1,Yaraşır Yasin1,Huri Gazi2,Aydıngöz Üstün1

Affiliation:

1. Department of Radiology, Hacettepe University School of Medicine, Ankara, Turkey.

2. Department of Orthopedics and Traumatology, Hacettepe University School of Medicine, Ankara, Turkey.

Abstract

Background: Suboptimal positioning on Grashey view radiographs may limit the prognosticating potential of the critical shoulder angle (CSA) for shoulder disorders. Purpose: To investigate whether radiography optimized according to the latest research is reliable for measuring CSA in comparison with magnetic resonance imaging (MRI) featuring 3-dimensional (3D) zero echo time (ZTE) sequencing, which accentuates the contrast between cortical bone and surrounding soft tissue with high fidelity. Study Design: Cohort study (diagnosis); Level of evidence, 2. Methods: Patients with shoulder pain were prospectively and consecutively enrolled. All patients had Grashey view radiographs as well as 3.0-T MRI scans with isotropic 3D ZTE sequencing. Acceptable positioning on the radiographs was determined using the ratio of the transverse to longitudinal (RTL) diameter of the lateral glenoid outline; radiographs with an RTL ≥0.25 were repeated. Two observers independently measured the CSA on the radiographs and the coronal oblique reformatted ZTE images, the latter including verification of measurement points by cross-referencing against images from other planes. Reliability of measurements between observers and modalities was analyzed with the intraclass correlation coefficient (ICC). The paired-samples t test was used to compare the differences between imaging modalities. Results: Enrolled were 65 patients (35 female and 30 male; mean age, 40.2 years; range, 25-49 years). Radiographs with optimal positioning (RTL < 0.25) were attained after a mean of 1.6 exposures (range, 1-4); the mean RTL was 0.09 (range, 0-0.20). Interobserver agreement of CSA was excellent for radiographs (ICC = 0.91; 95% CI, 0.84-0.94) and good for ZTE MRI scans (ICC = 0.85; 95% CI, 0.71-0.92). Intermodality agreement of CSA between radiographs and ZTE MRI scans was moderate (ICC = 0.66; 95% CI, 0.48-0.73). The CSA was significantly different between an optimal radiograph (30.7° ± 4.3°) and ZTE MRI scan (31.8° ± 3.8) ( P = .005). Subgroup analysis revealed no significant differences in CSA measurement between ZTE MRI scans and Grashey view radiographs with an RTL of <0.1 ( P = .08). Conclusion: CSA measurement on ZTE MRI scans with anatomic point cross-referencing was significantly different from that on Grashey view radiographs, even with optimal positioning, and radiography may necessitate more than 1 exposure. An RTL of <0.1 ensured reliability of radiographs when other standards of sufficient x-ray exposure were met.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3