Complete Restoration of Native Glenoid Width Improves Glenohumeral Biomechanics After Simulated Latarjet

Author:

Rauck Ryan C.1,Brusalis Christopher M.2,Jahandar Amirhossein3,Lamplot Joseph D.4,Dines David M.2,Warren Russell F.2,Gulotta Lawrence V.2,Kontaxis Andreas3,Taylor Samuel A.2

Affiliation:

1. Division of Sports Medicine, Department of Orthopaedic Surgery, The Ohio State University College of Medicine, Columbus, Ohio, USA

2. Sports Medicine Institute, Department of Orthopedic Surgery, Hospital for Special Surgery, New York, New York, USA

3. Department of Biomechanics, Hospital for Special Surgery, New York, New York, USA

4. Division of Sports Medicine, Department of Orthopaedic Surgery, Emory University School of Medicine, Atlanta, Georgia, USA

Abstract

Background: The amount of glenoid width that must be restored with a Latarjet procedure in order to reestablish glenohumeral stability has not been determined. Purpose/Hypothesis: The purpose of this article was to determine the percentage of glenoid width restoration necessary for glenohumeral stability after Latarjet by measuring anterior humeral head translation and force distribution on the coracoid graft. The hypothesis was that at least 100% of glenoid width restoration with Latarjet would be required to maintain glenohumeral stability. Study Design: Controlled laboratory study. Methods: Nine cadaveric shoulders were prepared and mounted on an established shoulder simulator. A lesser tuberosity osteotomy (LTO) was performed to allow accurate removal of glenoid bone. Coracoid osteotomy was performed, and the coracoid graft was sized to a depth of 10 mm. Glenoid bone was sequentially removed, and Latarjet was performed using 2 screws to reestablish 110%, 100%, 90%, and 80% of native glenoid width. The graft was passed through a subscapularis muscle split, and the LTO was repaired. A motion tracking system recorded glenohumeral translations, and force distribution was recorded using a TekScan pressure sensor secured to the glenoid face and coracoid graft. Testing conditions included native; LTO; Bankart tear; and 110%, 100%, 90%, and 80% of glenoid width restoration with Latarjet. Glenohumeral translations were recorded while applying an anteroinferior load of 44 N at 90° of humerothoracic abduction and 0° or 45° of glenohumeral external rotation. Force distribution was recorded without an anteroinferior load. Results: Anterior humeral head translation progressively increased as the proportion of glenoid width restored decreased. A marked increase in anterior humeral head translation was found with 90% versus 100% glenoid width restoration (10.8 ± 3.0 vs 4.1 ± 2.6 mm, respectively; P < .001). Greater glenoid bone loss also led to increased force on the coracoid graft relative to the native glenoid bone after Latarjet. A pronounced increase in force on the coracoid graft was seen with 90% versus 100% glenoid width restoration ( P < .001). Conclusion: Anterior humeral head translation and force distribution on the coracoid graft dramatically increased when <100% of the native glenoid width was restored with a Latarjet procedure. Clinical Relevance: If a Latarjet is unable to fully restore the native glenoid width, surgeons should consider alternative graft sources to minimize the risk of recurrent instability or coracoid overload.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine