Biomechanical Analysis of Coracoid Stability After Coracoplasty: How Low Can You Go?

Author:

Heilmann Lukas F.1,Sussiek Julia1,Raschke Michael J.1,Langer Martin F.1,Frank Andre1,Wermers Jens1,Michel Philipp A.1,Dyrna Felix1,Schliemann Benedikt1,Katthagen J. Christoph1

Affiliation:

1. University Hospital Muenster (WWU), Muenster, Germany.

Abstract

Background: Arthroscopic coracoplasty is a procedure for patients affected by subcoracoid impingement. To date, there is no consensus on how much of the coracoid can be resected with an arthroscopic burr without compromising its stability. Purpose: To determine the maximum amount of the coracoid that can be resected during arthroscopic coracoplasty without leading to coracoid fracture or avulsion of the conjoint tendon during simulated activities of daily living (ADLs). Study Design: Controlled laboratory study. Methods: A biomechanical cadaveric study was performed with 24 shoulders (15 male, 9 female; mean age, 81 ± 7.9 years). Specimens were randomized into 3 treatment groups: group A (native coracoid), group B (3-mm coracoplasty), and group C (5-mm coracoplasty). Coracoid anatomic measurements were documented before and after coracoplasty. The scapula was potted, and a traction force was applied through the conjoint tendon. The stiffness and load to failure (LTF) were determined for each specimen. Results: The mean coracoid thicknesses in groups A through C were 7.2, 7.7, and 7.8 mm, respectively, and the mean LTFs were 428 ± 127, 284 ± 77, and 159 ± 87 N, respectively. Compared with specimens in group A, a significantly lower LTF was seen in specimens in group B ( P = .022) and group C ( P < .001). Postoperatively, coracoids with a thickness ≥4 mm were able to withstand ADLs. Conclusion: While even a 3-mm coracoplasty caused significant weakening of the coracoid, the individual failure loads were higher than those of the predicted ADLs. A critical value of 4 mm of coracoid thickness should be preserved to ensure the stability of the coracoid process. Clinical Relevance: In correspondence with the findings of this study, careful preoperative planning should be used to measure the maximum reasonable amount of coracoplasty to be performed. A postoperative coracoid thickness of 4 mm should remain.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3