Best implant choice for coracoid graft fixation during the Latarjet procedure depends on patients’ morphometric considerations

Author:

Boutsiadis Achilleas,Bampis Ioannis,Swan John,Barth Johannes

Abstract

Abstract Purpose To assess the anthropometric dimensions of the coracoid process and the glenoid articular surface and to determine possible implications with the different commercially available Latarjet fixation techniques. Methods In a total of 101 skeletal scapulae the glenoid length (GL), the glenoid width (GW), the coracoid length (CL), the coracoid width (CW) and the coracoid thickness (CTh) were measured. In order to assess the ability of the transferred coracoid to restore the glenoid anatomy we created a hypothetical model of 10%, 15%, 20%, 25% and 30% glenoid bone loss. We analyzed four common surgical fixation techniques for the Latarjet procedure (4.5 mm screws, 3.75 mm screws, 3.5 mm screws, and 2.8 mm button). The distances from the superior-inferior and medio-lateral limits of the coracoid using the four different fixation methods were calculated. We hypothesized that the “safe distance” between the implant and the coracoid osteotomy should be at least equal to the diameter of the implant. Results The intra and inter-observer reliability tests were almost perfect for all measurements. The mean GH was 36.8 ± 2.5 mm, the GW 26.4 ± 2.2 mm, the CL 23.9 ± 3 mm, the CW 13.6 ± 2.mm, and the mean CTh was 8.7 ± 1.3 mm. The CL was < 25 mm in 46% of the cases. In cases with 25% and 30% bone loss, the coracoid graft restored the glenoid anatomy in 96% and 79.2% of the cases. With the use of the 4.5 mm screws the “safe distance” was present in 56% of the cases, with the 3.75 mm screws in 85%, with the 3.5 mm screws in 87%, and with the 2.8 mm button in 98% of the cases. The distance from the medio-lateral limit of the coracoid could be significantly increased (up to 9 mm) when smaller-button implants are used. Conclusions The coracoid graft could not always restore glenoid defects of 30%. Larger implants could be positioned too close to the osteotomy and the “medio-lateral offset” of the coracoid could be increased with smaller implants.

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3