Abstract

Background: Several classification systems based on arthroscopy have been used to describe lesions of the ligamentum teres (LT) in young active patients undergoing hip-preserving surgery. Inspection of the LT and associated lesions of the adjuvant fovea capitis and acetabular fossa is limited when done arthroscopically but is much more thorough during open surgical hip dislocation. Therefore, we propose a novel grading system based on our findings during surgical dislocation comprising the full spectrum of ligamentous-fossa-foveolar complex (LFFC) lesions. Purpose: To determine (1) intraobserver reliability and (2) interobserver reproducibility of our new grading system. Study Design: Cohort study (diagnosis); Level of evidence, 3. Methods: We performed this validation study on 211 hips (633 images in total) with surgical hip dislocation (2013-2021). We randomly selected 5 images per grade for each LFFC item to achieve an equal representation of all grades (resulting in 75 images). The ligament, fossa, and fovea were subcategorized into normal, inflammation, degeneration, partial, and complete defects. All surgeries were performed in a standardized way by a single surgeon. The femur was disarticulated using a bone hook, the LT was inspected, documented and resected, then the fossa and fovea were documented with the femoral head in full dislocation using a 70° arthroscope. Six observers with different levels of expertise in hip-preserving surgery independently conducted the measurements twice, and intraclass correlation coefficients (ICC) were calculated to determine (1) intraobserver reliability and (2) interobserver reproducibility of the novel grading system. Results: For intraobserver reliability, excellent ICCs were found in both the junior and the experienced raters for grading the ligament, fossa, fovea, and total LFFC (ICCs ranged from 0.91 to 0.99 for the LFFC score). We found excellent interobserver reproducibility between raters for all items of the LFFC (all interobserver ICCs ≥ 0.76). Conclusion: Our new grading system for lesions of the LFFC is highly reliable and reproducible. It covers the full spectrum of damage more precisely than arthroscopic classifications do and offers a scientific basis for standardized intraoperative evaluation.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3