How Strong Is the Ligamentum Teres of the Hip? A Biomechanical Analysis

Author:

Stetzelberger Vera M.12,Nishimura Haruki2,Hollenbeck Justin F. M.2,Garcia Alexander2ORCID,Brown Justin R.2,Schwab Joseph M.1ORCID,Philippon Marc J.2,Tannast Moritz1ORCID

Affiliation:

1. Department of Orthopaedic Surgery and Traumatology, HFR Cantonal Hospital, University of Fribourg, Fribourg, Switzerland

2. Steadman Philippon Research Institute, The Steadman Clinic, Vail, CO, USA

Abstract

Background Intraarticular hip pain represents a substantial clinical challenge, with recent studies implicating lesions in the ligamentum teres as potential contributors. Even more so, damage to the ligamentum teres is particularly prevalent among young patients undergoing joint-preserving interventions. Although several studies have investigated the biomechanical attributes of the ligamentum teres, inconsistencies in reported findings and reliance on cadaveric or animal models have raised concerns regarding the extrapolation of results to clinical practice. Furthermore, there is a lack of research examining ligamentum teres biomechanics specifically within the relevant patient cohort—individuals who benefit from joint-preserving surgical interventions. Questions/purposes We sought (1) to determine the biomechanical properties (ultimate load to failure, tensile strength, stiffness, and elastic modulus) of fresh-frozen ligaments from patients undergoing surgical hip dislocation, and (2) to identify patient-specific factors that are associated with them. Methods This was an institutional review board–approved study on intraoperatively harvested ligamentum teres from 74 consecutive patients undergoing surgical hip dislocation for joint preservation (August 2021 to September 2022). After the exclusion of patients with previous surgery, posttraumatic deformities, avascular necrosis, slipped capital femoral epiphysis, and Perthes disease, 31 ligaments from 31 patients were analyzed. The mean age of the study group was 27 ± 8 years, and 61% (19) of participants were male. The main indication for surgery was femoroacetabular impingement. Standardized AP pelvic and axial radiographs and CT scans were performed in all patients for better radiological description of the population and to identify associated radiological factors. The ligament was thoroughly transected at its origin on the fossa acetabuli and at the insertion area on the fovea capitis and stored at -20°C until utilization. Specimens were mounted to a materials testing machine via custom clamps that minimized slippage and the likelihood of failure at the clamp. Force-displacement and stress-strain curves were generated. Ultimate failure load (N), tensile strength (MPa), stiffness (N/mm), and elastic modulus (MPa) were determined. Using a multivariate regression analysis and a subgroup analysis, we tested demographic, degenerative, and radiographic factors as potential associated factors. Results The ligamentum teres demonstrated an ultimate load to failure of 126 ± 92 N, and the tensile strength was 1 ± 1 MPa. The ligaments exhibited a stiffness of 24 ± 15 N/mm and an elastic modulus of 7 ± 5 MPa. After controlling for potential confounding variables like age, fossa/fovea degeneration, and acetabular/femoral morphologies, we found that female sex was an independent factor for higher tensile strength, stiffness, and elastic modulus. Excessive femoral version was independently associated with lower load to failure (HR 122 [95% CI 47 to 197]) and stiffness (HR 15 [95% CI 2 to 27]). Damage to the acetabular fossa was associated with reduced load to failure (HR -93 [95% CI -159 to -27]). Conclusion Overall, the ligamentum teres is a relatively weak ligament. Sex, degeneration, and excessive femoral version are influencing factors on strength of the ligamentum teres. The ligamentum teres exhibits lower strength compared with other joint-stabilizing ligaments, which calls into question its overall contribution to hip stability. Clinical Relevance Young patients undergoing hip-preserving surgery are the population at risk for ligamentum teres lesions. Baseline values for load to failure, tensile strength, elastic modulus, and stiffness are needed to better understand those lesions in this cohort of interest.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3