The biomechanical effect of changes in cancellous bone density on synthetic femur behaviour

Author:

Nicayenzi B1,Shah S12,Schemitsch E H23,Bougherara H1,Zdero R12

Affiliation:

1. Department of Mechanical and Industrial Engineering, Ryerson University, Toronto, ON, Canada

2. Martin Orthopaedic Biomechanics Lab, St. Michael’s Hospital, Toronto, ON, Canada

3. Department of Surgery, Faculty of Medicine, University of Toronto, Toronto, ON, Canada

Abstract

Biomechanical researchers increasingly use commercially available and experimentally validated synthetic femurs to mimic human femurs. However, the choice of cancellous bone density for these artificial femurs appears to be done arbitrarily. The aim of the work reported in this paper was to examine the effect of synthetic cancellous bone density on the mechanical behaviour of synthetic femurs. Thirty left, large, fourth-generation composite femurs were mounted onto an Instron material testing system. The femurs were divided evenly into five groups each containing six femurs, each group representing a different synthetic cancellous bone density: 0.08, 0.16, 0.24, 0.32, and 0.48 g/cm3. Femurs were tested non-destructively to obtain axial, lateral, and torsional stiffness, followed by destructive tests to measure axial failure load, displacement, and energy. Experimental results yielded the following ranges and the coefficient of determination for a linear regression ( R2) with cancellous bone density: axial stiffness (range 2116.5–2530.6 N/mm; R2 = 0.94), lateral stiffness (range 204.3–227.8 N/mm; R2 = 0.08), torsional stiffness (range 259.9–281.5 N/mm; R2 = 0.91), failure load (range 5527.6–11 109.3 N; R2 = 0.92), failure displacement (range 2.97–6.49 mm; R2 = 0.85), and failure energy (range 8.79–42.81 J; R2 = 0.91). These synthetic femurs showed no density effect on lateral stiffness and only a moderate influence on axial and torsional stiffness; however, there was a strong density effect on axial failure load, displacement, and energy. Because these synthetic femurs have previously been experimentally validated against human femurs, these trends may be generalized to the clinical situation. This is the first study in the literature to perform such an assessment.

Publisher

SAGE Publications

Subject

Mechanical Engineering,General Medicine

Cited by 33 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3