Wear of different materials for total hip replacement under adverse stop-dwell-start in vitro wear simulation conditions

Author:

Hadley Megan1,Hardaker Catherine1,Isaac Graham12,Fisher John2

Affiliation:

1. DePuy International Ltd, Leeds, UK

2. University of Leeds, Leeds, UK

Abstract

Hip simulation is a common technique for pre-clinical evaluation of wear performance of total hip arthroplasty. Standard techniques replicate kinematics of walking patterns of a typical patient. Attention has focussed in developing simulations of other typical patient daily activities to improve accuracy of wear predictions. A method for simulating stop-dwell-start motion during patient walking and the effect on 36-mm metal-on-metal total hip arthroplasty was previously presented by the authors. This study sought to extend the previous work to look at the effect of these conditions on ceramic-on-ceramic, metal-on-polyethylene and ceramic-on-polyethylene bearings. Two stop-dwell-start protocols were used: one reproducing average patient movement patterns and one examining more severe conditions. For all materials tested, no significant increase in wear was observed under average stop-dwell-start conditions, suggesting the bearing types tested are robust to this type of activity. A significant increase in wear was observed for metal-on-metal, metal-on-polyethylene and ceramic-on-polyethylene bearings under severe stop-dwell-start conditions, this was attributed to depletion of lubricant in the bearing during the dwell period. A greater relative increase in wear was observed for metal-on-metal bearings compared with metal-on-polyethylene and ceramic-on-polyethylene bearings. This may be explained by the contributions of the different lubrication mechanisms in each bearing type. Wear of ceramic-on-ceramic was very low in all tests, suggesting normal measurement variation was masking any effect of the adverse conditions. It was not possible to determine any effect of the different activities. These results emphasise the importance of exploring adverse patient activity simulations. The increase in wear rate associated with an adverse activity such as seen in stop-dwell-start motion, has to be considered in the context of the frequency of the adverse activity cycle relative to other activities such as standard continuous walking, to determine the impact on the total wear in a given time period.

Publisher

SAGE Publications

Subject

Mechanical Engineering,General Medicine

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3