Abstract
Generation of wear debris and wear particle-induced osteolysis are the main limitations of metal-on-polyethylene artificial joints. Cross-linked polyethylene has been recently used, particularly in hip replacements, as an alternative material to conventional ultrahigh molecular weight polyethylene due to its superior wear resistance. This study focused on the wear behaviour of cross-linked polyethylene under different contact stresses in order to make interpretations of its long-term in-vivo performance. A 50-station SuperCTPOD (pin-on-disc) machine was used to investigate the influence of contact stress on the wear of cross-linked polyethylene pins which were articulated against cobalt chromium discs. It was found that the wear rate of cross-linked polyethylene was lower at higher contact stresses.