Strain gauge analysis of implant-supported, screw-retained metal frameworks: Comparison between different manufacturing technologies

Author:

Degidi Marco1,Caligiana Gianni2,Francia Daniela2,Liverani Alfredo2,Olmi Giorgio2,Tornabene Francesco3

Affiliation:

1. Private Practice, Bologna, Italy

2. Department of Industrial Engineering, University of Bologna, Bologna, Italy

3. Department of Civil, Chemical, Environmental, and Materials Engineering, University of Bologna, Bologna, Italy

Abstract

Over the past decades, the technological development in the medical field, coupled with the ongoing scientific research, has led to the development and improvement of dental prostheses supported by screw-retained metal frameworks. A key point in the manufacture of the framework is the achievement of a passive fit, intended as the capability of an implant-supported reconstruction to transmit minimum strain to implant components as well as to the surrounding bone, when subject to any load. The fitting of four different kinds of screw-retained metal frameworks was tested in this article. They differ both in materials and manufacturing process: two frameworks are made by casting, one framework is made by computer-aided design and computer-aided manufacturing and one framework is made by electric resistance spot welding (WeldONE, DENTSPLY Implants Manufacturing GmbH, Mannheim, Germany). The passivity of the frameworks was evaluated on the entire system, composed of a resin master cast, the implant analogues embedded in the cast and the frameworks. Strains were recorded by means of an electrical strain gauge connected to a control unit for strain gauge measurements. The experimental tests were carried out in the laboratories of the Department of INdustrial engineering at the University of Bologna. The results of the test campaigns, which compared three samples for each technological process, showed that no significant differences exist between the four framework types. In particular, the frameworks made by the resistance welding approach led to a mechanical response that is well comparable to that of the other tested frameworks.

Publisher

SAGE Publications

Subject

Mechanical Engineering,General Medicine

Cited by 9 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3