Background: Impella devices are used for mechanical circulatory support in patients with cardiogenic shock or those undergoing high-risk percutaneous coronary intervention (PCI). Anticoagulation protocols in this population are not well established and are complicated by concomitant use of purge solutions containing unfractionated heparin (UFH) and intravenous UFH continuous infusion (CI) for systemic anticoagulation. Objectives: To evaluate thrombotic and bleeding complications when using a novel UFH protocol with a reduced initial UFH CI dose of 6 units/kg/hour targeting an anti-Xa goal of 0.3 to 0.5 units/mL in patients receiving Impella support. Methods: This single-center, retrospective study included 41 patients on Impella support who received an UFH purge solution and/or an IV UFH infusion. The primary outcome was overall composite bleeding. Secondary outcomes included thrombotic events and systemic UFH exposure. An exploratory analysis was performed to identify risk factors for bleeding. Results: Anti-Xa values were in therapeutic range 46% of the time while on support (interquartile range 16.6%-75%), with a median IV UFH dose of 6 units/kg/hour. The overall bleeding rate was 29.2%, with 6 minor bleeds and 2 major bleeds with no fatal bleeding or intracranial hemorrhage. Rate of overall thrombosis was 4.9%, including 1 ischemic stroke and 1 occurrence of limb ischemia. Conclusion: Use of a modified UFH protocol to target an anti-Xa goal of 0.3 to 0.5 units/mL resulted in bleeding and thrombotic event rates similar to previous literature. This protocol utilizing an initial rate of 6 units/kg/hour may be a useful approach to achieve therapeutic anticoagulation while accounting for UFH exposure from the purge solution and minimizing need for frequent calculations.

Publisher

SAGE Publications

Subject

Pharmacology (medical),Pharmacology,Pharmacy

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3