Heparin Monitoring with an Anti-Xa Protocol Compared to Activated Clotting Time in Patients on Temporary Mechanical Circulatory Support

Author:

Feih Joel T.12ORCID,Wallskog Kirsten E.3,Rinka Joseph R. G.14,Juul Janelle J.1,Rein Lisa2,Gaglianello Nunzio2,Baumann Kreuziger Lisa M.2,Joyce David L.2,Tawil Justin N.2

Affiliation:

1. Froedtert & the Medical College of Wisconsin, Milwaukee, WI, USA

2. Medical College of Wisconsin, Milwaukee, WI, USA

3. Adventist Health, Portland, OR, USA

4. Concordia University Wisconsin, Mequon, WI, USA

Abstract

Background: Temporary mechanical circulatory support (tMCS) devices are used for patients with severe cardiac or respiratory failure; however, these patients are at high risk for clotting and bleeding. The best method to monitor heparin in these patients has not been established. Objective: To determine the risks for bleeding and clotting while monitoring heparin with either anti-Xa or activated clotting time (ACT) in tMCS patients. Methods: A retrospective cohort study was conducted on tMCS patients who received heparin adjusted according to an anti-Xa or ACT protocol. The primary outcome was incidence of major bleeding. Pertinent secondary outcomes were individual components of the primary outcome, clotting events, and time to therapeutic range. Results: There were 103 patients included in the study: 53 in the ACT group and 50 in the anti-Xa group. Overall, there were 30 (56.6%) patients with major bleeding in the ACT group, compared with 16 (32%) patients in the anti-Xa group ( P = 0.017). An anti-Xa–based protocol was associated with a decreased hazard of major bleeding (hazard ratio = 0.388 [0.215-0.701]; P = 0.002) in the univariate analysis. In the multivariable analysis, an anti-Xa protocol remained associated with a significantly lower hazard of bleeding. Findings were similar when broken down into more discrete subgroups of the entire cohort, extracorporeal membrane oxygenation life support (ECMO), and non-ECMO groups. Conclusion and Relevance: Anti-Xa monitoring was associated with a lower hazard of bleeding during tMCS compared to an ACT-based protocol. Further studies should evaluate if anti-Xa monitoring should be preferentially used in tMCS.

Publisher

SAGE Publications

Subject

Pharmacology (medical)

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3