Predictors of Hardware Removal in Orthopaedic Trauma Patients Undergoing Syndesmotic Ankle Fixation With Screws

Author:

Bragg Jack T.1ORCID,Masood Raisa M.2,Spence Samara S.3,Citron Julia E.3,Moon Andrew S.1,Salzler Matthew J.1,Ryan Scott P.1

Affiliation:

1. Department of Orthopaedic Surgery, Tufts Medical Center, Boston, MA, USA

2. SUNY–Upstate Medical University, Syracuse, NY, USA

3. Tufts University School of Medicine, Boston, MA, USA

Abstract

Background: Indications for removal of syndesmotic screws are not fully elucidated. This study aimed to determine factors related to elective syndesmotic screw removal. Methods: Patients who underwent fixation of ankle syndesmotic injuries were included. Screw removal was offered after a minimum of 12 weeks after surgery for pain, stiffness or patient desire to remove painful or broken hardware. Patient demographics, surgical data, distance of the syndesmotic screw from the joint, location of the screw at the physeal scar, and number of syndesmotic screws placed were collected for all patients. Bivariate and multivariate analyses were performed to determine the relationship between patient characteristics and screw removal and independent predictors of hardware removal. Results: Of 160 patients, 60 patients (38%) with an average age of 36.1 (range: 18-84) years underwent elective syndesmotic screw removal at a mean of 7 (range, 3-47) months after initial fixation. The most common reason for screw removal (50/60 patients) was ankle stiffness and pain (83%). Patients who underwent screw removal were more likely to be younger (36.1 years ± 13.0 vs 46.6 years ± 18.2, P < .001) and have a lower ASA score (2 ± 0.8 vs 2.1 ± 0.7, P = .003) by bivariate analysis. Of patients who underwent screw removal, 21.7% (13/60) had a broken screw at the time of removal. Whether the screw was placed at the physeal scar was not significantly associated with patient decision for hardware removal ( P = .80). Conclusion: Younger and healthier patients were more likely to undergo elective removal of syndesmotic hardware. Screw distance from joint and screw placement at the physeal scar were not significantly associated with hardware removal. Level of Evidence: Level III, retrospective cohort study.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3