Predicting arterio-venous fistula failure by urea–method derived access blood flow in chronic hemodialysis patients

Author:

Lelamali Kumtorn1ORCID,Papirachanat Piyarek1,Puavilai Thitiya1

Affiliation:

1. Renal Unit, Department of Medicine, Rajavithi Hospital, Department of Medical Services, Ministry of Public Health, College of Medicine, Rangsit University, Bangkok, Thailand

Abstract

Background: Dialysis access is an essential part of hemodialysis. Determining the access blood flow (Qa) can help predict arterio-venous fistula thrombosis. Qa determination by the urea method, which was previously described in the past is simple and is available in most of the dialysis units but was not be able to predict arterio-venous fistula thrombosis. Aim: To compare the efficacy of Qa determination by the urea method and by ultrasound dilution methods in predicting arterio-venous fistula failure. Methods: Qa was measured by urea method and by ultrasound dilution simultaneously, every 3 months for a period of 1 year, in stable chronic hemodialysis patients with arterio-venous fistula. Arterio-venous fistula failure determined by clinical parameters and confirmed by Doppler ultrasound before sending the patient for interventional angioplasty. Results: This study enrolled a total of 16 patients, with 63% being male, 75% with lower-arm arterio-venous fistula and around 43% with previously done angioplasty. 59-Qa measurements were done, and 6 patients underwent angioplasty (one patient for severe upper limb edema, one for access thrombosis, and four for access dysfunction). Qa determination by the urea method had non-significantly lower Qa, (745 mL/min (interquartile range: 509–1143) and 779 mL/min (interquartile range: 530–1160), (p = 0.58)) and high correlation (r = 0.83, p < 0.001) to Qa by ultrasound dilution. The cut-off criteria with its sensitivity and specificity in predicting the access failure were 440 mL/min, 66.67%, and 96.15% for Qa determination by the urea and 400 mL/min, 66.67% and 90.38% for Qa by ultrasound dilution, respectively, with no difference in the area under the receiver operating characteristic curve. Conclusion: Measurement of Qa determination by the urea method is well correlated with Qa by ultrasound dilution and can be used to predict vascular access failure.

Publisher

SAGE Publications

Subject

Nephrology,Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3