A Novel Catheter System for Totally Implantable Intravenous Drug Therapy: Assessment of Catheter Function and Patency with Trepostinil Therapy

Author:

Morris M.1,Phares K.2,Zaccardelli D.2,Ujhelyi M.R.1

Affiliation:

1. Cardiac Rhythm Disease Management Medtronic Inc, Minneapolis, MN - USA

2. United Therapeutics Corp, Durham, NC - USA

Abstract

Background Catheter failure, either due to dislodgment, occlusion or infection is the leading complication of chronic intravenous drug therapy. Better drug delivery techniques are required to advance life saving therapies that require this delivery method. This study evaluated the chronic performance of a fully implantable drug delivery system that incorporates a novel intravenous catheter. The system was designed to reduce complications associated with intravascular drug delivery including catheter occlusion, breakage, migration, and infection. Methods Twelve canines were implanted with a novel central venous catheter (Model 10642; Medtronic, Minneapolis, MN) connected to a totally implanted programmable drug pump (Model 8637 SynchroMed II®, Medtronic). The drug delivery systems infused saline (n=6) or treprostinil (n=6) (Remodulin®; United Therapeutics, Research Triangle Park, NC) for either 12 or 26 weeks at a continuous flow rate of 540 μL/day. Catheter performance was assessed at 0 (implant), 2, 4, 8, 12, 16, 20, and 24 weeks by quantifying delivery pressure, delivery volume and steady state Treprostinil concentrations. Results All catheters remained patent and free of complications for the duration of the study. Analysis of pressure waveforms during bolus delivery showed low and unchanged catheter resistance throughout the study. Measurement of pump delivery volume accuracy showed that the delivered volume was statistically similar to the calculated delivery (product of flow rate and elapsed time). Measurement of plasma treprostinil levels showed stable concentrations over the study period. There were no catheter dislodgments or breakage. Pathology showed all catheters free from fibrosis and thrombus and minimal changes to the vascular endothelium. Conclusions The Model 10642 vascular catheter along with the SynchroMed II implantable drug delivery system showed promising performance in a chronic animal model.

Publisher

SAGE Publications

Subject

Nephrology,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3