How to carry out monthly blood flow surveillance of fistula in large-scale hemodialysis units: A cross-sectional study

Author:

Mo Ya-wen123,Sun Chun-yan123,Song Li1,Zhou Li-fang12,Zhuang Ting-ting4,Zhong Mi1,Zheng Shu-qian25,Chen Ying-gui12,Chen Yuan-han1,Liu Shuang-xin1,Liang Xin-ling1,Fu Xia12ORCID

Affiliation:

1. Division of Nephrology, Guangdong Provincial People’s Hospital, Guangdong Academy of Medical Sciences, Guangzhou, China

2. School of Nursing, Southern Medical University, Guangzhou, China

3. Ya-wen Mo and Chun-yan Sun contributed equally to the article.

4. Department of Rehabilitation Medicine, Guangdong Second Traditional Chinese Medicine Hospital, Guangzhou, China

5. Division of Nephrology, Guangzhou Nansha Central Hospital, Guangzhou, China

Abstract

Background: The important effect of regular blood flow surveillance on arteriovenous fistula maintenance is emphasized. The ultrasonic dilution technique for blood flow surveillance can be performed during hemodialysis, but there are some limitations. Blood flow is traditionally measured by duplex Doppler ultrasound during the nondialysis period. However, the surveillance workload for arteriovenous fistula has increased with the rapid increase in the hemodialysis population size. Efficient methods for blood flow surveillance during hemodialysis are needed. Methods: Eighty-four hemodialysis patients with a forearm radiocephalic arteriovenous fistula were enrolled in this cross-sectional study. Each received blood flow measurements using ultrasonic dilution technique and duplex Doppler ultrasound during hemodialysis. Duplex Doppler ultrasound measurements included the blood flow of the brachial artery and radial artery. The correlations between these variables were analyzed. Results: The correlation coefficients ( r) between flow measured by ultrasonic dilution technique and brachial artery flow measured by duplex Doppler ultrasound, between flow measured by ultrasonic dilution technique and radial artery flow measured by duplex Doppler ultrasound, and between brachial artery flow and radial artery flow measured by duplex Doppler ultrasound were 0.724, 0.784, and 0.749, respectively (all p < 0.001). Conclusion: Blood flow measured by ultrasonic dilution technique was positively correlated with blood flow measured by duplex Doppler ultrasound during hemodialysis, suggesting that duplex Doppler ultrasound can be used to monitor the trends in the blood flow of the brachial artery and radial artery for timely intervention to improve patency during hemodialysis.

Funder

Guangdong Provincial Scientific Planning Project

Publisher

SAGE Publications

Subject

Nephrology,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3