Assessment of volume flow rate in arteriovenous fistulas with a novel ultrasound Doppler device (earlybird): Trend analysis, comparison of methods, and inter- and intra-rater reliability

Author:

Holst-Jæger Emilie1,Barstad Marthe1,Salvesen Øyvind2,Torp Hans34,Seternes Arne356,Pettersen Erik Mulder367ORCID

Affiliation:

1. Faculty of Medicine and Health Sciences, Norwegian University of Science and Technology, Trondheim, Norway

2. Clinical Research Unit, Department of Clinical and Molecular Medicine, Norwegian University of Science and Technology, Trondheim, Norway

3. Department of Circulation and Medical Imaging, Norwegian University of Science and Technology, Trondheim, Norway

4. CIMON Medical, NTNU Technology Transfer AS, Trondheim, Norway

5. Section of Vascular Surgery, Department of Surgery, Trondheim University Hospital, St. Olavs Hospital, Trondheim, Norway

6. Research Center for Medical Equipment, Technology and Innovation, St. Olavs Hospital, Trondheim, Norway

7. Department of Surgery, Sørlandet Hospital Kristiansand, Kristiansand, Norway

Abstract

Background: An accessible tool is required to analyze volume flow trends in arteriovenous fistulas for hemodialysis. Earlybird, an easy-to-place ultrasound Doppler device, has shown comparable accuracy to duplex ultrasound. In this study, we compared volume flow measurements obtained with duplex ultrasound and the dilution technique to an enhanced earlybird device, featuring a dual Doppler probe system, eliminating the requirement for a known insonation angle. Methods: Nine patients with a distal radiocephalic arteriovenous fistula were monitored for 12 months with regular volume flow measurements. Correlation and inter- and intra-class reliability analyses were conducted. Results: An overall moderate correlation was observed between earlybird and duplex ultrasound or dilution technique (intraclass correlation coefficient = 0.606 (95% confidence interval 0.064, 0.721) and 0.581 (0.039, 0.739), respectively). Duplex ultrasound compared to dilution measurements, demonstrated an overall moderate correlation (0.725 (0.219, 0.843)). Correlation between earlybird and duplex ultrasound was stronger for the arteriovenous fistula (0.778 (0.016, 0.901)) than the brachial artery (0.381 (−0.062, 0.461)). For earlybird, inter-rater reliability was excellent for the arteriovenous fistula (0.907 (0.423, 0.930)) and poor for the brachial artery (0.430 (0.241, 0.716)). Duplex ultrasound showed a good inter-rater reliability (arteriovenous fistula: 0.843 (0.610, 0.871), brachial artery: 0.819 (0.477, 0.864)). The overall intra-rater reliability was good for duplex ultrasound (rater A: 0.893 (0.727, 0.911); rater B: 0.853 (0.710, 0.891)), while excellent for earlybird (rater A: 0.905 (0.819, 0.928); rater B: 0.921 (0.632, 0.969)). Conclusion: We observed a weaker correlation in the measurements of volume flow rates in arteriovenous fistulas when obtained using earlybird compared to dilution technique, unlike the comparison between duplex ultrasound and the dilution technique. However, inter-rater reliability for the arteriovenous fistula was excellent with earlybird and good with duplex ultrasound, indicating the potential of earlybird as a tool for frequent measurements, enabling trend surveillance and predicting adverse outcomes.