Lead Discovery for Microsomal Prostaglandin E Synthase Using a Combination of High-Throughput Fluorescent-Based Assays and RapidFire Mass Spectrometry

Author:

Leveridge Melanie V.1,Bardera Ana Isabel2,LaMarr William3,Billinton Andrew4,Bellenie Ben4,Edge Colin5,Francis Peter5,Christodoulou Erica6,Shillings Anthony6,Hibbs Martin6,Fosberry Andrew6,Tanner Rob6,Hardwicke Philip6,Craggs Peter6,Sinha Yugesh1,Elegbe Oluseyi1,Alvarez-Ruiz Emilio2,Martin-Plaza Jose Julio2,Barroso-Poveda Vanessa2,Baddeley Stuart1,Chung Chun-wa5,Hutchinson Jonathan6

Affiliation:

1. Departments of Screening and Compound Profiling, GlaxoSmithKline, Stevenage, UK

2. Screening and Compound Profiling, Centro de Investigatión Básica, GlaxoSmithKline, Tres Cantos, Madrid, Spain

3. Agilent Technologies, Wakefield, MA, USA

4. Neurosciences CEDD, GlaxoSmithKline, New Frontiers Science Park, Harlow, Essex, UK

5. Computational and Structural Chemistry, GlaxoSmithKline, Stevenage, UK

6. Biological Reagents and Assay Development, GlaxoSmithKline, Stevenage, UK

Abstract

Microsomal prostaglandin E synthase-1 (mPGES-1) represents an attractive target for the treatment of rheumatoid arthritis and pain, being upregulated in response to inflammatory stimuli. Biochemical assays for prostaglandin E synthase activity are complicated by the instability of the substrate (PGH2) and the challenge of detection of the product (PGE2). A coupled fluorescent assay is described for mPGES-1where PGH2 is generated in situ using the action of cyclooxygenase 2 (Cox-2) on arachidonic acid. PGE2 is detected by coupling through 15-prostaglandin dehydrogenase (15-PGDH) and diaphorase. The overall coupled reaction was miniaturized to 1536-well plates and validated for high-throughput screening. For compound progression, a novel high-throughput mass spectrometry assay was developed using the RapidFire platform. The assay employs the same in situ substrate generation step as the fluorescent assay, after which both PGE2 and a reduced form of the unreacted substrate were detected by mass spectrometry. Pharmacology and assay quality were comparable between both assays, but the mass spectrometry assay was shown to be less susceptible to interference and false positives. Exploiting the throughput of the fluorescent assay and the label-free, direct detection of the RapidFire has proved to be a powerful lead discovery strategy for this challenging target.

Publisher

Elsevier BV

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3