Affiliation:
1. Department of Physics, Goethe University of Frankfurt, Frankfurt, Germany
Abstract
Grouted connections are structural joints formed by a cementitious grout cast between two concentric circular tubes. They are widely used in the offshore construction of oil and gas platforms, and for offshore wind turbines (monopiles and jackets). However, their application in offshore wind turbine installations can be critical due to the high bending moments coming from wind loading. Recently, it was found that grouted connections show limited performance in offshore wind turbine installations leading to settlements between the steel tubes and steel/grout debonding. Hence, structural health monitoring techniques for grouted connections are needed that ensure a safe and reliable operation of offshore wind turbines. This short communication describes the successful application of electromechanical impedance spectroscopy for damage detection in grouted connections.
Funder
Bundesministerium für Wirtschaft und Energie
Cited by
13 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献