Energy and exergy analysis of a downstream single-row air washer at different droplet diameters for air cooling application

Author:

Huang Minhua1,Wang Haiqiao1,Tian Feng1,Huang Junxin2,Chen Shiqiang13ORCID,Jiang Jiachuan4,Liu Ruihong4

Affiliation:

1. School of Resource, Environment and Safety Engineering, Hunan University of Science and Technology, Xiangtan, China

2. School of Safety and Environment Engineering, Hunan Institute of Technology, Hengyang, China

3. Hunan Provincial Engineering Techniques Research Centre of Mine Ventilation & Dedusting Equipment, Xiangtan, China

4. Fankou Lead-zinc Mine, Shenzhen Zhongjin Lingnan Non-ferrous Metal Company Limited, Shaoguan, China

Abstract

This study proposes a downstream single-row air washer for air cooling. The theoretical energy and exergy balance models were established at different droplet diameters and verified by the experimental data. Based on the abovementioned theoretical relationship, the single performance indicator of heat exchange efficiency (HEE) and exergy efficiency was quantitatively analyzed; a comprehensive analysis method of two indicators was proposed, combining HEE and exergy efficiency, and a numerical simulation was carried out. Results show that the smaller the droplet diameter and the larger the water–air ratio, the lower the dry-bulb temperature of the outlet air and the higher the HEE and exergy flux destruction. When the droplet diameter is less than 440 μm, the droplet diameter does not affect exergy efficiency and dry-bulb temperature. When the droplet diameter is larger than 440 μm, the droplet diameter is positively correlated with the air outlet dry-bulb temperature and exergy efficiency; in contrast, the water–gas ratio is negatively correlated with the air outlet dry-bulb temperature. An engineering case reveals that when the air outlet temperature is less than 34°C, the critical water–gas ratio can be set as 2.6 (mass ratio). At this time, the HEE is more than 90%, the exergy efficiency is more than 60%, and the critical value of droplet diameter is 440 μm. The research results provide an essential theoretical basis for the optimization of engineering design calculation.

Funder

National Natural Science Foundation of China

Project of Hunan Provincial Natural Science Foundation of China

Publisher

SAGE Publications

Subject

Mechanical Engineering

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3