Performance of StatSensor Point-of-Care Device for Measuring Creatinine in Patients With Chronic Kidney Disease and Postkidney Transplantation

Author:

Nataatmadja Melissa123ORCID,Fung Angela W. S.4ORCID,Jacobson Beryl5,Ferera Jack6,Bernstein Eva6,Komenda Paul78,Mattman Andre4,Seccombe David5,Levin Adeera369

Affiliation:

1. Sunshine Coast Hospital and Health Service, Birtinya, Queensland, Australia

2. Faculty of Medicine, The University of Queensland, Brisbane, Australia

3. Division of Nephrology, The University of British Columbia, Vancouver, Canada

4. Department of Pathology and Laboratory Medicine, St. Paul’s Hospital, Vancouver, BC, Canada

5. CEQAL Inc, Vancouver, BC, Canada

6. BC Provincial Renal Agency, Vancouver, Canada

7. Max Rady Department of Medicine, Section of Nephrology, University of Manitoba, Winnipeg, Canada

8. Chronic Disease Innovation Centre, Winnipeg, MB, Canada

9. Division of Nephrology, St. Paul’s Hospital, Vancouver, BC, Canada

Abstract

Background:The StatSensor is a point-of-care device which measures creatinine in capillary whole blood. Previous studies reported an underestimation of the creatinine measurements at high creatinine concentrations and were performed in the prestandardization era for creatinine.Objective:This accuracy-based study evaluates the use of this device in kidney-transplanted patients and those with chronic kidney disease (CKD).Design:Cross-sectional diagnostic accuracy study.Setting:Nephrology outpatient clinic in an urban tertiary center.Participants:Adults with CKD or a functioning kidney transplant.Measurements:Duplicate StatSensor creatinine measurements were performed on capillary whole blood samples collected by direct fingerstick and SAFE-T-FILL collection device. Results were compared with simultaneous venous blood sampling for serum and plasma creatinine measured by an enzymatic method on the Roche Integra 400 mainframe analyzer with traceability to the ID-GC-MS (isotope dilution gas chromatography mass spectrometry) reference method.Methods:Deming regression, Pearson correlation coefficient, and Bland-Altman analysis were used to assess accuracy and comparability between capillary whole blood measured by StatSensor and plasma creatinine measured by routine analyzer with traceability to the reference method. Estimated glomerular filtration (eGFR) rates were calculated using the Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) equation and concordance with Kidney Disease Improving Global Outcomes (KDIGO) CKD stage classification was evaluated.Results:There were 60 participants (mean age = 61.9 ± 15.0 years, 55% men, 33% transplant, mean plasma creatinine = 137 ± 59 µmol/L). Bland-Altman analysis indicated a positive mean bias of 12.7 µmol/L between StatSensor fingerstick creatinine measurement and plasma creatinine. Comparison of eGFR (CKD-EPI) calculated from the StatSensor fingerstick creatinine versus plasma creatinine showed misclassification across all KDIGO CKD stages. Postanalytical correction of the bias did not improve misclassifications. The use of mean of duplicate StatSensor creatinine results did not improve performance compared with the use of singlet results.Limitations:Single center, limited participant numbers.Conclusions:The results of our study suggest that the limiting characteristics of the StatSensor device are not only bias, but also imprecision. The level of imprecision observed may influence clinical decision-making and limit the usefulness of StatSensor as a CKD screening tool. If choosing to utilize it for either screening for or monitoring CKD, it is essential that clinicians understand the limitations of point-of-care devices and apply this knowledge to test interpretation.

Publisher