Abstract

Purpose: In medial open-wedge high tibial osteotomy (HTO) hinge axis and osteotomy plane influence the resulting anatomy, but accurate angular quantifications using 3D-planning-simulations are lacking. The objectives of this study were developing a standardized and validated 3D-planning method of an HTO and to perform several simulated realignments to explain unintended anatomy changes. Methods: The cutting direction of the main osteotomy was defined parallel to the medial tibial slope and the hinge axis 1.5 cm distal to the lateral plateau. For interobserver testing, this 3D planning was performed on 13 digital models of human tibiae by two observers. In addition, four different hinge axis positions and five differently inclined osteotomy planes each were simulated. The osteotomy direction ranged from medial 0°–30° anteromedial, while the tilt of the osteotomy plane compared to the tibial plateau was −10° to +10°. All anatomic angular changes were calculated using 3D analysis. Results: Multiple HTO plannings by two medical investigators using standardized procedures showed only minimal differences. In the 3D-simulation, each 10° rotation of the hinge axis resulted in a 1.7° significant increase in slope. Tilting the osteotomy plane by 10° resulted in significant torsional changes of 2°, in addition to minor but significant changes in the medial proximal tibial angle (MPTA). Conclusion: Standardized 3D-planning of the HTO can be performed with high reliability using two-observer planning. 3D-simulations suggest that control of the osteotomy plane is highly relevant to avoid unintended changes in the resulting anatomy, but this can be a helpful tool to modify specific angles in different pathologies in the HTO.

Funder

German Knee Society e.V. (Deutsche Kniegesellschaft e.V.

Publisher

SAGE Publications

Subject

Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3