Accuracy of 3D-planned patient specific instrumentation in high tibial open wedge valgisation osteotomy

Author:

Fucentese Sandro F.,Meier Patrick,Jud LukasORCID,Köchli Gian-Luca,Aichmair Alexander,Vlachopoulos Lazaros,Fürnstahl Philipp

Abstract

Abstract Purpose High tibial osteotomy (HTO) is an effective treatment option in early osteoarthritis. However, preoperative planning and surgical execution can be challenging. Computer assisted three-dimensional (3D) planning and patient-specific instruments (PSI) might be helpful tools in achieving successful outcomes. Goal of this study was to assess the accuracy of HTO using PSI. Methods All medial open wedge PSI-HTO between 2014 and 2016 were reviewed. Using pre- and postoperative radiographs, hip-knee-ankle angle (HKA) and posterior tibial slope (PTS) were determined two-dimensionally (2D) to calculate 2D accuracy. Using postoperative CT-data, 3D surface models of the tibias were reconstructed and superimposed with the planning to calculate 3D accuracy. Results Twenty-three patients could be included. A mean correction of HKA of 9.7° ± 2.6° was planned. Postoperative assessment of HKA correction showed a mean correction of 8.9° ± 3.2°, resulting in a 2D accuracy for HKA correction of 0.8° ± 1.5°. The postoperative PTS changed by 1.7° ± 2.2°. 3D accuracy showed average 3D rotational differences of − 0.1° ± 2.3° in coronal plane, − 0.2° ± 2.3° in transversal plane, and 1.3° ± 2.1° in sagittal plane, whereby 3D translational differences were calculated as 0.1 mm ± 1.3 mm in coronal plane, − 0.1 ± 0.6 mm in transversal plane, and − 0.1 ± 0.6 mm in sagittal plane. Conclusion The use of PSI in HTO results in accurate correction of mechanical leg axis. In contrast to the known problem of unintended PTS changes in conventional HTO, just slight changes of PTS could be observed using PSI. The use of PSI in HTO might be preferable to obtain desired correction of HKA and to maintain PTS.

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine

Cited by 56 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3