Effects of differential pressure measurement characteristics on high pressure-EGR estimation error in SI-engines

Author:

Dadam Sumanth Reddy1ORCID,Ali Imtiaz1,Zhu Di1,Kumar Vivek1

Affiliation:

1. Powertrain Research and Advanced Engineering, Ford Motor Company, Dearborn, MI, USA

Abstract

With proper control, exhaust gas recirculation (EGR) can be used for knock mitigation in SI engines, enabling fuel economy improvements through more optimal combustion phasing and lower fuel-enrichment at high loads. Due to significant pressure pulsations across the EGR valve, estimating the mass flow rates at transient and reversing flows across the valve can be challenging. Many systems utilize the pressure drop across a restriction in a flow path as an indication of mass flow. In automotive applications, the measurement of the pressure drop is accomplished by the use of a delta pressure sensor and the pressure drop mechanism could be a sharp edge orifice or other restrictions such as a valve opening. This technique works well for steady-state flow; however, if pressure fluctuations exist, especially at higher frequencies, this method of measuring mass flow can have large errors. The accuracy of EGR mass flow estimation based on a pressure differential (Δ P) measurement and the steady compressible flow orifice equation is investigated for various Δ P sensor frequencies and sampling rates on Ford 3.5L V6 GTDI and 2.3L I4 GTDI engines. This paper identifies the two major contributors of the error are the long length of the gauge lines and the close location of the downstream tap. The long length of the gauge line results in resonances at low frequency which affects the sensor performance. When the downstream tap is placed too close to the orifice, the accuracy of sensor reading is reduced. The proposed solution suggests keeping the gauge line as short as possible and the downstream tap at least two diameters away from the orifice and using a high-speed sensor. The result from engine testing shows a great improvement in the measurement accuracy by 43%. It is demonstrated that using a slow responding sensor with a low sample rate leads to erroneous mass flow calculation when significant pressure pulsations exist. A minimum of 1 kHz sample rate is needed to increase the accuracy of the EGR estimate within ±1%.

Publisher

SAGE Publications

Subject

Mechanical Engineering,Ocean Engineering,Aerospace Engineering,Automotive Engineering

Cited by 9 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3