Impact of aortic stent-graft oversizing on outcomes of the chimney endovascular technique based on a new analysis of the PERICLES Registry

Author:

Donas Konstantinos P1,Usai Marco V2ORCID,Taneva Gergana T1ORCID,Criado Frank J3,Torsello Giovanni B1,Kubilis Paul4,Scali Salvatore4,Veith Frank J56

Affiliation:

1. Department of Vascular Surgery, St Franziskus Hospital, Münster, Germany

2. Clinic of Vascular and Endovascular Surgery, University of Münster, Münster, Germany

3. Division of Vascular Surgery, MedStar Union Memorial Hospital, Baltimore, USA

4. University of Florida, Gainesville, USA

5. New York University, New York, USA

6. Cleveland Clinic, Cleveland, USA

Abstract

Objective Chimney endovascular aortic aneurysm repair is gaining ever greater acceptance. However, persistent gutters leading to type IA endoleaks represent an unsolved issue. The aim of the current study was to analyze the impact of abdominal endograft oversizing to the occurrence of this phenomenon. Methods The PERformance of the snorkel/chImney endovascular teChnique in the treatment of compLex aortic PathologiesES registry includes the largest experience with chimney endovascular aortic aneurysm repair from 13 vascular centers in Europe and the U.S. Prospectively collected data from centers with standard use of the Endurant stent-graft and balloon-expandable covered stents as chimney grafts only were included in the present analysis. The parameter which varied was the degree of oversizing of the aortic stent-graft classifying the cohort in two groups, group A (20% and less oversizing) and group B (>20% of oversizing). The primary endpoint was the incidence of persistent type IA endoleak needed reintervention. Secondary endpoints were all-cause mortality and freedom from reintervention. Results Group A included 21 patients while group B 144. The mean preoperative pathology’s neck length and diameter was 5.8 mm (±4.4) versus 4.9 mm (±3.8) and 27.6 mm (±4.7) versus 24.9 mm (±3.7) for group A and group B, respectively. The mean length of the new sealing zone after chimney graft placement was similar for both groups (group A versus group B; 17.9 mm versus 18.3 mm, respectively, P = .21). The percentage of oversizing of the aortic stent-graft ranged between 13.8 and 20% versus 22.2 and 30%, for group A and group B, respectively. Patients of group A had more type 1A endoleaks, (14.3%) versus patients of group B (2.1%) based on the first follow-up imaging, P = .02. The incidence of persistent type IA endoleaks needing a reintervention was 14.3 and 1.4% for the group A and group B, respectively, P = .01. The mean volume of contrast medium used was greater in group A versus group B with 239 ml versus150 ml, P = .05. Additionally, 14.3% of patients of group A experienced acute renal failure compared to those in group B which was 1.0%, P = .01. Conclusions Oversizing of ideally 30% of the Endurant stent-graft is associated with significant lower incidence of type IA endoleaks requiring reintervention for patients treated by chimney endovascular aortic aneurysm repair.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging,General Medicine,Surgery

Cited by 20 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3