Effects of Initial Graft Tension on the Tibiofemoral Compressive Forces and Joint Position after Anterior Cruciate Ligament Reconstruction

Author:

Brady Mark F.1,Bradley Michael P.1,Fleming Braden C.1,Fadale Paul D.1,Hulstyn Michael J.1,Banerjee Rahul1

Affiliation:

1. Bioengineering Labs, Department of Orthopaedics, Brown Medical School/Rhode Island Hospital, Providence, Rhode Island

Abstract

Background The initial tension applied to an anterior cruciate ligament graft at the time of fixation modulates knee motion and the tibiofemoral compressive loads. Purpose To establish the relationships between initial graft tension, tibiofemoral compressive force, and the neutral tibiofemoral position in the cadaveric knee. Study Design Controlled laboratory study. Methods The tibiofemoral compressive forces and joint positions were determined in the anterior cruciate ligament-intact knee at 0°, 20°, and 90° of knee flexion. The anterior cruciate ligament was excised and reconstructed with a patellar tendon graft using graft tensions of 1, 15, 30, 60, and 90 N applied at 0°, 20°, and 90° of knee flexion. The compressive forces and neutral positions were compared between initial tension conditions and the anterior cruciate ligament-intact knee. Results Increasing initial graft tension increased the tibiofemoral compressive forces. The forces in the medial compartment were 1.8 times those in the lateral compartment. The compressive forces were dependent on the knee angle at which the tension was applied. The greatest compressive forces occurred when the graft was tensioned with the knee in extension. An increase in initial graft tension caused the tibia to rotate externally compared with the anterior cruciate ligament-intact knee (1.5° and 7.7° of external rotation when tensioned to 90 N at 0° and 90° of knee flexion, respectively). Increases in initial graft tension also caused a significant posterior translation of the tibia relative to the femur (0.9 and 5.3 mm of posterior translation when tensioned to 90 N at 0° and 90° of knee flexion, respectively). Conclusion Different initial graft tension protocols produced predictable changes in the tibiofemoral compressive forces and joint positions. Clinical Relevance The tibiofemoral compressive force and neutral joint position were best replicated with a low graft tension (1-15 N) when using a patellar tendon graft.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

Cited by 63 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3