Affiliation:
1. Department of Orthopaedics and Rehabilitation, University of Rochester Medical Center, Rochester, New York, USA
Abstract
Background: Previous studies comparing stability between single- and double-row arthroscopic bony Bankart repair techniques focused only on the measurements of tensile forces on the bony fragment without re-creating a more physiologic testing environment. Purpose: To compare dynamic stability and displacement between single- and double-row arthroscopic repair techniques for acute bony Bankart lesions in a concavity-compression cadaveric model simulating physiologic conditions. Study Design: Controlled laboratory study. Methods: Testing was performed on 13 matched pairs of cadaveric glenoids with simulated bony Bankart fractures with a defect width of 25% of the inferior glenoid diameter. Half of the fractures were repaired with a double-row technique, and the contralateral glenoids were repaired with a single-row technique. To determine dynamic biomechanical stability and ultimate step-off of the repairs, a 150-N load and 2000 cycles of internal-external rotation at 1 Hz were applied to specimens to simulate early rehabilitation. Toggle was quantified throughout cycling with a coordinate measuring machine. Three-dimensional spatial measurements were calculated. After cyclic loading, the fracture displacement was measured. Results: The bony Bankart fragment–glenoid initial step-off was found to be significantly greater ( P < .001) for the single-row technique (mean, 896 µm; SD, 282 µm) compared with the double-row technique (mean, 436 µm; SD, 313 µm). The motion toggle was found to be significantly greater ( P = .017) for the single-row technique (mean, 994 µm; SD, 711 µm) compared with the double-row technique (mean, 408 µm; SD, 384 µm). The ultimate interface displacement was found to be significantly greater ( P = .029) for the single-row technique (mean, 1265 µm; SD, 606 µm) compared with the double-row technique (mean, 795 µm; SD, 398 µm). Conclusion: Using a concavity-compression glenohumeral cadaveric model, we found that the double-row arthroscopic fixation technique for bony Bankart repair resulted in superior stability and decreased displacement during simulated rehabilitation when compared with the single-row repair technique. Clinical Relevance: The findings from this study may help guide surgical decision-making by demonstrating superior biomechanical properties (improved initial step-off, motion toggle, and interface displacement) of the double-row bony Bankart repair technique when compared with single-row fixation. The double-row repair construct demonstrated increased stability of the bony Bankart fragment, which may improve bony Bankart healing.
Subject
Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine
Cited by
13 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献