A Biomechanical, Cadaveric Evaluation of Single- Versus Double-Row Repair Techniques on Stability of Bony Bankart Lesions

Author:

Greenstein Alexander S.1,Chen Raymond E.1,Knapp Emma1,Brown Alexander M.1,Roberts Aaron1,Awad Hani A.1,Voloshin Ilya1

Affiliation:

1. Department of Orthopaedics and Rehabilitation, University of Rochester Medical Center, Rochester, New York, USA

Abstract

Background: Previous studies comparing stability between single- and double-row arthroscopic bony Bankart repair techniques focused only on the measurements of tensile forces on the bony fragment without re-creating a more physiologic testing environment. Purpose: To compare dynamic stability and displacement between single- and double-row arthroscopic repair techniques for acute bony Bankart lesions in a concavity-compression cadaveric model simulating physiologic conditions. Study Design: Controlled laboratory study. Methods: Testing was performed on 13 matched pairs of cadaveric glenoids with simulated bony Bankart fractures with a defect width of 25% of the inferior glenoid diameter. Half of the fractures were repaired with a double-row technique, and the contralateral glenoids were repaired with a single-row technique. To determine dynamic biomechanical stability and ultimate step-off of the repairs, a 150-N load and 2000 cycles of internal-external rotation at 1 Hz were applied to specimens to simulate early rehabilitation. Toggle was quantified throughout cycling with a coordinate measuring machine. Three-dimensional spatial measurements were calculated. After cyclic loading, the fracture displacement was measured. Results: The bony Bankart fragment–glenoid initial step-off was found to be significantly greater ( P < .001) for the single-row technique (mean, 896 µm; SD, 282 µm) compared with the double-row technique (mean, 436 µm; SD, 313 µm). The motion toggle was found to be significantly greater ( P = .017) for the single-row technique (mean, 994 µm; SD, 711 µm) compared with the double-row technique (mean, 408 µm; SD, 384 µm). The ultimate interface displacement was found to be significantly greater ( P = .029) for the single-row technique (mean, 1265 µm; SD, 606 µm) compared with the double-row technique (mean, 795 µm; SD, 398 µm). Conclusion: Using a concavity-compression glenohumeral cadaveric model, we found that the double-row arthroscopic fixation technique for bony Bankart repair resulted in superior stability and decreased displacement during simulated rehabilitation when compared with the single-row repair technique. Clinical Relevance: The findings from this study may help guide surgical decision-making by demonstrating superior biomechanical properties (improved initial step-off, motion toggle, and interface displacement) of the double-row bony Bankart repair technique when compared with single-row fixation. The double-row repair construct demonstrated increased stability of the bony Bankart fragment, which may improve bony Bankart healing.

Funder

university of rochester

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3