Radiographic Methods Are as Accurate as Magnetic Resonance Imaging for Graft Sizing Before Lateral Meniscal Transplantation

Author:

Ambra Luiz Felipe12,Kaleka Camila Cohen3,Debieux Pedro13,Almeida Julio Cesar4,Shah Nehal5,Cohen Moises13,Gomoll Andreas2

Affiliation:

1. Departamento de Ortopedia e Traumatologia, Escola Paulista de Medicina, Universidade Federal de São Paulo, São Paulo, Brazil

2. Department of Orthopedic Surgery, Hospital for Special Surgery, New York, USA

3. Hospital Israelita Albert Einstein, São Paulo, Brazil

4. Department of Radiology, Hospital do Coração, São Paulo, Brazil

5. Department of Radiology, Brigham and Women’s Hospital, Boston, Massachusetts, USA

Abstract

Background: Accurate allograft matching is deemed critical for meniscal transplantation; thus, precise measurements are essential to correctly calculate meniscal size. Several methods for meniscal sizing have been described, but there remains a discussion on which is the most accurate for the lateral meniscus. Purpose: To compare the accuracy of radiographic, anthropometric, and magnetic resonance imaging (MRI) methods of determining width and length of the lateral meniscus with actual dimensions after anatomic dissection. Study Design: Controlled laboratory study. Methods: Ten fresh-frozen human cadaveric knees without any evidence of meniscal or ligamentous injury were primarily imaged using radiography and MRI and subsequently underwent dissection to assess the anatomic size of each meniscus. Four methods were used to predict the size of the lateral menisci: anthropometric, radiographic (Pollard and Yoon), and MRI. Absolute differences in length and width between actual and predicted sizes were determined. Results: The anatomic lateral meniscal width and length were 33.01 ± 4.25 mm (mean ± SD; range, 24.84-40.18 mm) and 31.41 ± 5.06 mm (range, 25.2-40.05 mm), respectively. Regarding width, the anthropometric method demonstrated an absolute difference from anatomic measurement significantly greater when compared with the Pollard technique and MRI ( P = .002). Regarding length, the Pollard method presented an absolute difference significantly greater than all other techniques ( P = .003). In terms of the ability to measure width and length, MRI accurately predicted meniscal size within 10% of the anatomic size in 65% of measurements, the Yoon method in 54%, and the Pollard method in 20% ( P = .01). Radiographs tended to overestimate the true size of the lateral meniscus, while the anthropometric technique overestimated width in all specimens. Conclusion: This study demonstrated that MRI and the Yoon radiographic method are comparable in terms of accuracy for graft sizing before lateral meniscal transplantation. While MRI is useful, a contralateral MRI is required, which makes the Yoon radiographic method recommended given the ease and cost advantage. The original Pollard technique and the anthropometric method are not recommended. Clinical Relevance: Over- and undersizing of meniscal transplants has been implicated in graft failure. Therefore, increasing the reliability of preoperative meniscal measurements is deemed important for the success of meniscal allograft transplantation.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3