MRI-Based Characterization of Bone Anatomy in the Human Knee for Size Matching of a Medial Meniscal Implant

Author:

Elsner Jonathan J.1,Portnoy Sigal1,Guilak Farshid2,Shterling Avi1,Linder-Ganz Eran1

Affiliation:

1. Research & Development Center, Active Implants Corporation, Netanya 42505, Israel

2. Duke University Medical Center, Durham, NC 27710

Abstract

Allograft or synthetic menisci have been suggested as a means to restore contact pressures following meniscectomy. However, when the natural meniscus is severely damaged/absent, the necessary size cannot be determined according to the recipient size and there is a need to estimate it from magnetic resonance imaging (MRI) of the contralateral knee or the injured knee bones. The use of the contralateral-knee for size matching is problematic due to economic and practical reasons. Hence, there are significant advantages for a sizing algorithm based only on the candidate knee geometry. The aim of this study is to characterize midrange values and variability of knee dimensions and to develop a set of mathematical relations representing knee dimensions using a minimum of imaging-based bone measurements. Tibia, femur, and meniscus measurements were taken in 118 MRI scans and used to develop a representative parametric knee model in which all dimensions are expressed using tibia plateau width. The model was verified by comparing the predicted values to direct MRI measurements for 20 additional subjects by means of the Pearson correlation and Bland and Altman (1986, “Statistical Methods for Assessing Agreement Between Two Methods of Clinical Measurement,” Lancet, 1, pp. 307–310) plot. Anatomical parameters in the male knee were significantly larger (∼17%) compared with corresponding female measurements. However, most relations between tibia, femur, and meniscus measurements (43/56) were not significantly different between male and female populations (p≥0.05), indicating that differences between male and female joints are generally related to scaling and not shape. Dimensions predicted by the knee model were in a good agreement with dimensions measured directly from the MRI (R2>0.96) and the Bland and Altman plot indicated that ∼95% of data points were well within the ±2 standard deviation lines of agreement. The model proposed in this study is advantageous in being able to describe typical knee proportions for a given tibial width and can be used to predict the dimensions of a candidate knee based on a single measurement. The anatomical/anthropometric data presented in the study can be utilized in a sizing algorithm for artificial meniscal implants or in the design of artificial meniscus prostheses.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Reference33 articles.

1. Role of the Menisci in the Distribution of Stress in the Knee;Radin;Clin. Orthop. Relat. Res.

2. The Sensitivity of Tibiofemoral Contact Pressure to the Size and Shape of the Lateral and Medial Menisci;Haut Donahue;J. Orthop. Res.

3. Shock Absorption of Meniscectomized and Painful Knees: A Comparative In Vivo Study;Voloshin;J. Biomed. Eng.

4. Stabilizing Mechanisms of the Loaded and Unloaded Knee Joint;Hsieh;J. Bone Jt. Surg., Am. Vol.

5. The Effect of Medial Meniscectomy on Anterior-Posterior Motion of the Knee;Levy;J. Bone Jt. Surg., Am. Vol.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3