Biomechanical Evaluation of Minimally Invasive Repairs for Complete Acromioclavicular Joint Dislocation

Author:

Wellmann Mathias1,Zantop Thore1,Weimann Andre1,Raschke Michael J.1,Petersen Wolf1

Affiliation:

1. Department of Traumatology, Hand, and Reconstructive Surgery, University Hospital Muenster, Muenster, Germany

Abstract

Background The conventional coracoclavicular ligament augmentation with a single polydioxanone loop has been shown to have some pivotal disadvantages. Hypothesis A minimally invasive flip button/polydioxanone repair provides similar biomechanical properties to the conventional polydioxanone cerclage around the coracoid. However, the authors expected a difference in linear stiffness, ultimate load, and permanent elongation between suture anchor repairs and polydioxanone repairs. Study Design Controlled laboratory study. Methods The tensile fixation strength of 4 different minimally invasive repairs was tested in a porcine metatarsal model: (1) 1.3-mm single polydioxanone cerclage with a subcoracoidal flip button fixation, (2) 1.3-mm single polydioxanone cerclage, (3) Twinfix Ti 3.5-mm/Ultrabraid 2-suture anchor, and (4) Twinfix Ti 5.0-mm/Ultrabraid 2-suture anchor. The testing protocol included cyclic superoinferior loading and a subsequent load to failure trial. Results The flip button repair (646 N) and the conventional polydioxanone banding (663 N) revealed significant higher ultimate loads than did the suture anchor repairs (295 and 331 N, respectively; P < .001), whereas no significant differences were found for the elongation behavior under cyclic loading. Conclusion There was no significant difference between the 2 polydioxanone repairs. The ultimate load of the flip button procedure reaches the level of the native coracoclavicular ligament complex as it has been quantified in the literature. Clinical Relevance Although the biomechanical results comparing a minimally invasive flip button procedure versus a conventional polydioxanone cerclage are similar, the authors recommend the flip button procedure because of its minimally invasive approach and the secure subcoracoidal fixation technique with a minimized risk of anterior loop dislocation and neurovascular damage.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3