Biomechanical Analysis of the Pectoralis Major Tendon and Comparison of Techniques for Tendo-osseous Repair

Author:

Sherman Seth L.1,Lin Emery C.2,Verma Nikhil N.2,Mather Richard C.3,Gregory James M.2,Dishkin Justin2,Harwood Daniel P.2,Wang Vincent M.2,Shewman Elizabeth F.2,Cole Brian J.2,Romeo Anthony A.2

Affiliation:

1. Department of Orthopedic Surgery, Missouri Orthopaedic Institute, University of Missouri Health System, Columbia, Missouri

2. Division of Sports Medicine, Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, Illinois

3. Department of Orthopaedics, Duke University Medical Center, Durham, North Carolina

Abstract

Background: Various described surgical techniques exist for the repair of pectoralis major ruptures at the tendo-osseous junction. It is unclear how these techniques restore the native properties of the pectoralis major tendon because its biomechanical properties have not been described. Hypothesis: All repairs will have lower initial biomechanical profiles than the native attachment, and transosseous sutures will demonstrate improved initial biomechanical performance compared with anchors or buttons. Study Design: Controlled laboratory study. Methods: Twenty-four fresh-frozen cadaveric shoulders were randomized to 4 equal groups, including 3 experimental repair groups and 1 control group of intact pectoralis major tendons. The characteristics of the native anatomic footprint were recorded, and the experimental groups underwent pectoralis detachment, followed by subsequent repair. The restoration of the anatomic footprint was recorded. All specimens were tested with cyclic loading and load-to-failure protocols with load, displacement, and optical marker data simultaneously collected. Results: Under cyclic loading, the intact specimens demonstrated a significantly higher secant stiffness (74.8 ± 1.6 N/mm) than the repair groups (endosteal Pec Button [PB], 46.2 ± 6.4 N/mm; suture anchor [SA], 45.9 ± 8.7 N/mm; transosseous [TO], 44.2 ± 5.5 N/mm). Measured as a percentage change, the PB and SA groups showed a significantly higher initial excursion than the intact group (PB, 24.0% ± 11.7%; SA, 17.5% ± 6.9%; intact, 2.2% ± 1.0%), and the PB group demonstrated a significantly higher cyclic elongation than the intact group (PB, 7.5% ± 2.9%; intact, 1.5% ± 1.5%). Under load-to-failure testing, the intact group showed a significantly greater maximum load (1454.8 ± 795.7 N) and linear stiffness (221.0 ± 111.7 N/mm) than the 3 repair groups (PB, 353.5 ± 88.3 N and 63.5 ± 6.9 N/mm; SA, 292.0 ± 73.3 N and 77.0 ± 7.8 N/mm; TO, 359.2 ± 110.4 N and 64.5 ± 14.1 N/mm, respectively). All repair constructs failed via suture pulling through the tendon. Conclusion: The biomechanical characteristics of the transosseous repair, suture anchors, or Pec Button repair were inferior to those of the native pectoralis tendon. There was no significant difference in any of the biomechanical outcomes among the repair groups. Further refinement and evaluation of suture technique and configuration in pectoralis major repair should be considered. Clinical Relevance: Transosseous repair, suture anchors, and endosteal Pec Buttons appear to confer similar biomechanical integrity for pectoralis major repair. Restricting early activities to thresholds below the identified failure loads seems prudent until soft tissue healing to bone is reliably achieved.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3