Biomechanical Evaluation of Bioabsorbable versus Metallic Screws for Posterior Cruciate Ligament Inlay Graft Fixation

Author:

Gupta Aman12,Lattermann Christian3,Busam Matthew4,Riff Andrew15,Bach Bernard R.1,Wang Vincent M.1

Affiliation:

1. Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, Illinois

2. Department of Bioengineering, University of Illinois at Chicago, Chicago, Illinois

3. Department of Orthopaedic Surgery, University of Kentucky College of Medicine, Lexington, Kentucky

4. Cincinnati Sports Medicine, Research and Education Foundation, Cincinnati, Ohio

5. Georgetown Medical School, Washington, DC

Abstract

Background Although a tibial inlay technique for posterior cruciate ligament reconstruction is advantageous, metallic screw fixation of the bone block is required. This may pose problems for future surgery (eg, osteotomies, total knee replacement). Hypothesis There is no significant difference in the biomechanical integrity of bone block fixation using stainless steel versus bioabsorbable screw fixation of the tibial inlay graft in posterior cruciate ligament reconstruction. Study Design Controlled laboratory study. Methods Fourteen human cadaveric knees were randomized to receive either stainless steel or bioabsorbable screw fixation of a bone—patellar tendon—bone graft. Cyclic tensile testing of each construct was performed, followed by a load-to-failure test. Digital video digitization was used to optically determine tendon graft deformation. Results Cyclic creep deformation showed no significant difference between the 2 groups ( P = .8). The failure load (stainless steel, 461 ± 231 N; bioabsorbable, 638 ± 492 N; P = .7) and linear stiffness (stainless steel, 116 ± 22 N/mm, bioabsorbable, 106 ± 44 N/mm; P = .6) also showed no significant difference between the 2 groups. Optically measured graft deformation was not significant for distal ( P = .7) and midsubstance ( P = .8) regions, while proximal deformation was significantly higher for bioabsorbable fixation ( P = .02). All samples failed at the tibial insertion site with the tibial bone block fracturing at the screws. Conclusion Bioabsorbable screw fixation using a tibial inlay technique does not compromise the strength and stiffness characteristics afforded by metallic fixation. From a biomechanical perspective, bioabsorbable screws are a viable alternative to metal in the context of tibial inlay reconstruction. Clinical Relevance Use of bioabsorbable fixation can potentially eliminate future hardware problems after posterior cruciate ligament reconstruction using a tibial inlay technique.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

Cited by 23 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3