Clinical and Radiological Outcomes After Hamstring Anterior Cruciate Ligament Reconstructions: Comparison Between Fixed-Loop and Adjustable-Loop Cortical Suspension Devices

Author:

Choi Nam-Hong1,Yang Bong-Seok2,Victoroff Brian N.3

Affiliation:

1. Department of Orthopaedic Surgery, Eulji Medical Center, Seoul, Korea

2. Department of Orthopaedic Surgery, Gwangmyeong Sungae Hospital, Gwangmyeong, Korea

3. Department of Orthopaedic Surgery, Case Western Reserve University, Cleveland, Ohio, USA

Abstract

Background: Few studies have compared clinical and radiological outcomes after hamstring anterior cruciate ligament (ACL) reconstruction with fixed-loop and adjustable-loop cortical suspension devices. Purpose/Hypothesis: The purpose of this retrospective study was to compare clinical outcomes and tunnel widening after hamstring ACL reconstructions with fixed- and adjustable-loop cortical suspension devices. The hypothesis was that compared with femoral graft fixation with the fixed-loop device, fixation with the adjustable-loop device would show similar clinical outcomes and would result in less tunnel widening after hamstring ACL reconstruction. Study Design: Cohort study; Level of evidence, 3. Methods: A total of 117 consecutive patients underwent hamstring ACL reconstruction at a single institution. The fixed-loop cortical suspension device was used in 67 patients, and the adjustable-loop cortical suspension device was used in 50 patients. All patients were observed for a minimum of 2 years. Postoperative knee laxity was evaluated with the Lachman test, pivot-shift test, and KT-1000 arthrometer. Functional evaluations were performed by use of the Lysholm score and the Tegner activity scale. On anteroposterior (AP) and lateral radiographs, the measured diameters of the femoral tunnel at 1 year after surgery were compared with the diameter of the reamer used at surgery. The measured diameters of the tibial tunnel at 1 year after surgery were compared with those taken immediately after surgery. Results: The mean KT-1000 arthrometer laxity measurement was 1.5 ± 1.8 mm in the fixed-loop group and 1.2 ± 2.3 mm in the adjustable-loop group ( P = .530). Results of postoperative knee laxity evaluations and functional outcomes from both groups showed no statistically significant differences. However, the fixed-loop group showed significantly better stability in the pivot-shift test than did the adjustable-loop group ( P = .018). On AP radiographs, the mean diameter of the femoral and tibial tunnels increased by 42.2% ± 15.9% and 37.0% ± 17.8%, respectively, in the fixed-loop group and by 43.0% ± 15.4% and 36.8% ± 18.2% in the adjustable-loop group. On lateral radiographs, the mean diameter of the femoral and tibial tunnels increased by 38.1% ± 14.8% and 39.9% ± 13.8%, respectively, in the fixed-loop group and by 35.8% ± 12.2% and 38.1% ± 21.0% in the adjustable-loop group. No significant differences were found between the 2 groups in postoperative femoral and tibial tunnel widening on AP radiographs ( P = .801 and .951, respectively) or lateral radiographs ( P = .422 and .621, respectively). Conclusion: Compared with femoral fixation by use of the fixed-loop device, femoral fixation by use of the adjustable-loop device showed similar clinical outcomes but did not reduce tunnel widening after hamstring ACL reconstructions.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

Cited by 57 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3