Femoral Suspension Devices for Anterior Cruciate Ligament Reconstruction

Author:

Barrow Aaron E.1,Pilia Marcello23,Guda Teja3,Kadrmas Warren R.1,Burns Travis C.1

Affiliation:

1. San Antonio Military Medical Center, Fort Sam Houston, Texas

2. United States Army Institute of Surgical Research, Fort Sam Houston, Texas

3. University of Texas–San Antonio, San Antonio, Texas

Abstract

Background: Cortical suspension devices are commonly used for femoral graft fixation during anterior cruciate ligament (ACL) reconstructive surgery. Adjustable-length fixation devices provide technical advantages over fixed-length loops but may be more susceptible to lengthening during cyclic loading. Hypothesis: Both fixed-length and adjustable-length femoral cortical suspension devices would withstand ultimate loads greater than those normally experienced by the native ACL and would prevent clinically significant lengthening during prolonged cyclic loading. Study Design: Controlled laboratory study. Methods: Mechanical testing was performed on 3 ACL graft cortical suspensory devices by use of an extended cyclic loading (4500 cycles at 10-250 N) and pull-to-failure protocol. Two adjustable-length devices were additionally tested with the free suture ends tied. Results: Total displacement after 4500 cycles of tensioning at variable loads (expressed as mean ± SD) was 42.45 mm (±7.01 mm) for the Arthrex TightRope RT, 5.76 mm (±0.35 mm) for the Biomet ToggleLoc, and 1.34 mm (±0.03 mm) for the Smith & Nephew EndoButton CL Ultra ( P < .001). The Arthrex TightRope reached clinical failure of 3 mm lengthening after fewer cycles (1349 ± 316) than the Biomet ToggleLoc (2576 ± 73) ( P < .001). The Smith & Nephew EndoButton did not reach clinical failure during cyclic testing. With the free suture ends tied, after 4500 cycles, the Arthrex TightRope had a significant decrease in lengthening to 13.36 ± 1.86 mm ( P < .037) There was also a significant difference in ultimate load between the TightRope (809.11 ± 52.94 N) and the other 2 constructs ( P < .001). Conclusion: The ultimate load of all graft-fixation devices exceeded the forces likely to be experienced in a patient’s knee during the early postoperative rehabilitation period. However, the adjustable-length fixation devices experienced a clinically significant increase in loop lengthening during cyclic testing. This lengthening is partially caused by suture slippage into the adjustable-length loop. Clinical Relevance: Adjustable-length ACL graft cortical suspension devices lengthen under cyclic loads because free suture ends are pulled into the adjustable loop. This may allow for graft-fixation device lengthening during the acute postoperative period.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3