Biomechanical Comparison of Patellar Fixation Techniques in Medial Patellofemoral Ligament Reconstruction

Author:

Russ Samuel D.1,Tompkins Marc1,Nuckley David2,Macalena Jeffrey1

Affiliation:

1. Department of Orthopaedic Surgery, University of Minnesota, Minneapolis, Minnesota, USA

2. Biomechanical Laboratory, University of Minnesota, Minneapolis, Minnesota, USA

Abstract

Background: Multiple techniques for reconstruction of the medial patellofemoral ligament (MPFL) have been described; however, little is known about the biomechanical properties of these techniques. Fixation of the graft to the patella has not been studied in a human cadaveric model. Hypothesis/Purpose: The purpose of this study was to compare the ultimate failure load and stiffness of 2 different MPFL patellar fixation techniques: suture anchor fixation and interference screw fixation. The null hypothesis was that the suture anchor group would show no difference in the ultimate failure load and stiffness compared with the interference screw group. Study Design: Controlled laboratory study. Methods: Reconstruction of the MPFL with semitendinosus autografts was performed in 8 pairs of fresh-frozen cadaveric knees (16 knees total; mean age, 55.8 ± 7.7 years). The specimens were randomly assigned to 2 groups of 8 specimens each based on the method used to fix the graft to the medial patella: suture anchor or interference screw fixation. Each reconstruction technique was performed on 1 knee from the same cadaveric specimen. Suture anchor reconstruction was completed with 2 parallel 3.0-mm biocomposite suture anchors. Interference screw fixation was accomplished with two 4.75-mm biocomposite interference screws docked in parallel tunnels. The reconstructions were cyclically loaded for 10 cycles to 30 N and then tested to failure at a constant displacement rate of 6 mm/s with a line of pull parallel to the anchors or interference screws. Ultimate failure load (N), stiffness (N/mm), and mode of failure were recorded for each specimen. Results: The suture anchor group had a significantly lower mean failure load (201.54 ± 63.14 N) than the interference screw group (299.25 ± 99.87 N) ( P = .007). The suture anchor group also had significantly lower mean stiffness (20.60 ± 6.78 N/mm) compared with the interference screw group (34.66 ± 10.74 N/mm) ( P = .007). The most common mode of failure in the suture anchor group was failure at the graft-suture interface. In the interference screw group, the most common mode of failure was the tendon graft pulling out of the tunnel. Conclusion: Interference screw fixation to the medial patella was found to be significantly stronger than suture anchor fixation when comparing the ultimate failure load and stiffness. Clinical Relevance: This study compares the biomechanical properties of 2 commonly used methods for patellar graft fixation in MPFL reconstruction surgery. It supports the use of interference screw fixation based on the ultimate load and stiffness, although suture anchor fixation may be sufficient when compared with the native MPFL based on previously published data.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3