Are 4D Motion Sensors Valid and Reliable for Studying Baseball Pitching?

Author:

Loushin Stacy R.1,Verhoeven Martijn2,Christoffer Daniel J.3,Camp Christopher L.3,Kaufman Kenton R.1

Affiliation:

1. Motion Analysis Laboratory, Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota, USA

2. Minnesota Twins Baseball Club, Minneapolis, Minnesota, USA

3. Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota, USA

Abstract

Background: Baseball pitching injuries are on the rise. Inertial measurement units (IMUs) provide immediate feedback to players and coaches, allowing for collection outside of the traditional laboratory setting with real-world application. The 4D Motion system provides kinematics throughout the pitching motion and may be beneficial for individualized programs in the throwing athlete. A systematic analysis of these sensors has not been completed. Purpose: To evaluate the validity of the 4D Motion IMU system for analyzing the baseball pitching motion compared with marker-based motion capture, and evaluate the internal reliability and consistency of the device. Study Design: Controlled laboratory study. Methods: Ten high school pitchers participated in this study (10 male; 9 right-hand dominant; mean age, 16.6 ± 1.3 years; mean body mass index, 24.1 ± 3.9). Participants were simultaneously outfitted with six 4D Motion IMU sensors and retroreflective markers. The pitchers threw fastballs at maximum effort off a mound at the standard height and distance. A comparison was made between the IMUs and corresponding motion capture values for shoulder external rotation, elbow flexion, chest extension, pelvis and chest rotation velocity, and rotation acceleration. Results: Significant differences were found for 5 of 7 metrics analyzed. The IMU overreported most metrics, except for elbow flexion and pelvis rotation angular acceleration, where both positive and negative errors were observed. The root mean square error and percentage errors indicated smaller discrepancies for chest extension (4°± 5°) and pelvis (38 ± 19 deg/s) and chest (96 ± 42 deg/s) rotation velocity, with elbow flexion having the largest variance (21°± 9°). Conclusion: The values of the 4D Motion IMU system should not be considered equivalent when compared with marker-based motion capture studies. The system lacked internal consistency and reliability, with angular velocities being the most consistent. Caution should be used when using the metrics provided by an IMU-based system for individualized monitoring. Clinical Relevance: If found valid and reliable, IMUs could be used for longitudinal workload monitoring, individualized throwing and rehabilitation programs, and ultimately injury prevention. This study demonstrates that the data obtained from a 4D Motion system using Gen 3 sensors are not equivalent to the data obtained from a marker-based motion capture system.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3