Exploring wearable sensors as an alternative to marker-based motion capture in the pitching delivery

Author:

Boddy Kyle J.ORCID,Marsh Joseph A.ORCID,Caravan Alex,Lindley Kyle E.ORCID,Scheffey John O.,O’Connell Michael E.ORCID

Abstract

Background Improvements in data processing, increased understanding of the biomechanical background behind kinetics and kinematics, and technological advancements in inertial measurement unit (IMU) sensors have enabled high precision in the measurement of joint angles and acceleration on human subjects. This has resulted in new devices that reportedly measure joint angles, arm speed, and stresses to the pitching arms of baseball players. This study seeks to validate one such sensor, the MotusBASEBALL unit, with a marker-based motion capture laboratory. Hypothesis We hypothesize that the joint angle measurements (“arm slot” and “shoulder rotation”) of the MotusBASEBALL device will hold a statistically significant level of reliability and accuracy, but that the “arm speed” and “stress” metrics will not be accurate due to limitations in IMU technology. Methods A total of 10 healthy subjects threw five to seven fastballs followed by five to seven breaking pitches (slider or curveball) in the motion capture lab. Subjects wore retroreflective markers and the MotusBASEBALL sensor simultaneously. Results It was found that the arm slot (R = 0.975, P < 0.001), shoulder rotation (R = 0.749, P < 0.001), and stress (R = 0.667, P = 0.001 when compared to elbow torque; R = 0.653, P = 0.002 when compared to shoulder torque) measurements were all significantly correlated with the results from the motion capture lab. Arm speed showed significant correlations to shoulder internal rotation speed (R = 0.668, P = 0.001) and shoulder velocity magnitude (R = 0.659, P = 0.002). For the entire sample, arm slot and shoulder rotation measurements were on a similar scale, or within 5–15% in absolute value, of magnitude to measurements from the motion capture test, averaging eight degrees less (12.9% relative differences) and nine degrees (5.4%) less, respectively. Arm speed had a much larger difference, averaging 3,745 deg/s (80.2%) lower than shoulder internal rotation velocity, and 3,891 deg/s (80.8%) less than the shoulder velocity magnitude. The stress metric was found to be 41 Newton meter (Nm; 38.7%) less when compared to elbow torque, and 42 Nm (39.3%) less when compared to shoulder torque. Despite the differences in magnitude, the correlations were extremely strong, indicating that the MotusBASEBALL sensor had high reliability for casual use. Conclusion This study attempts to validate the use of the MotusBASEBALL for future studies that look at the arm slot, shoulder rotation, arm speed, and stress measurements from the MotusBASEBALL sensor. Excepting elbow extension velocity, all metrics from the MotusBASEBALL unit showed significant correlations to their corresponding metrics from motion capture and while some magnitudes differ substantially and therefore fall short in validity, the link between the metrics is strong enough to indicate reliable casual use. Further research should be done to further investigate the validity and reliability of the arm speed metric.

Publisher

PeerJ

Subject

General Agricultural and Biological Sciences,General Biochemistry, Genetics and Molecular Biology,General Medicine,General Neuroscience

Reference25 articles.

Cited by 41 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3