Estimation Failure Risk by 0.5-mm Differences in Autologous Hamstring Graft Diameter in Anterior Cruciate Ligament Reconstruction: A Meta-analysis

Author:

Itoh Masafumi123ORCID,Itou Junya13,Okazaki Ken1ORCID,Iwasaki Kiyotaka2345

Affiliation:

1. Department of Orthopedic Surgery, Tokyo Women’s Medical University, Shinjuku, Tokyo, Japan

2. Institute for Medical Regulatory Science, Comprehensive Research Organization, Waseda University, Shinjuku, Tokyo, Japan

3. Cooperative Major in Advanced Biomedical Sciences, Joint Graduate School of Tokyo Women’s Medical University and Waseda University, Shinjuku, Tokyo, Japan

4. Department of Modern Mechanical Engineering, Waseda University, Shinjuku, Tokyo, Japan

5. Department of Integrative Bioscience and Biomedical Engineering, Graduate School of Advanced Science and Engineering, Waseda University, Shinjuku, Tokyo, Japan

Abstract

Background: Because grafts are made in 0.5-mm increments clinically for anterior cruciate ligament (ACL) reconstruction, it is important to clarify how the failure rate decreases as the diameter increases. Moreover, it is important to know whether even a slight increase in the graft diameter decreases the risk of failure. Hypothesis: The risk of failure decreases significantly with each 0.5-mm increase in hamstring graft diameter. Study Design: Meta-analysis; Level of evidence, 4. Methods: The systematic review and meta-analysis have estimated the diameter-specific failure risk for each 0.5-mm increase in ACL reconstruction using autologous hamstring grafts. We searched for studies describing the relationship between graft diameter and failure rate published before December 1, 2021, in leading databases, such as PubMed, EMBASE, Cochrane Library, and Web of Science, according to the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines. We included studies using single-bundle autologous hamstring grafts to investigate the relationship between failure rate and graft diameter of 0.5-mm intervals with >1-year follow-up. Then, we calculated the failure risk caused by 0.5-mm differences in autologous hamstring graft diameter. Assuming Poisson distribution for the statistical model, we employed an extended linear mixed-effects model in the meta-analyses. Results: Five studies containing 19,333 cases were eligible. The meta-analysis revealed that the estimated value of the coefficient of diameter in the Poisson model was −0.2357 with a 95% CI of −0.2743 to −0.1971 ( P < .0001). With every 1.0-mm increase in diameter, the failure rate decreased by 0.79 (0.76-0.82) times. In contrast, the failure rate increased by 1.27 (1.22-1.32) times for each 1.0-mm decrease in diameter. The failure rate significantly decreased with each 0.5-mm increase in graft diameter in the range of <7.0 to >9.0 mm from 3.63% to 1.79%. Conclusion: The risk of failure decreased correspondingly with each 0.5-mm increase in graft diameter in the range of <7.0 to >9.0 mm. Failure is multifactorial; however, increasing the graft diameter as much as possible to match each patient’s anatomic space without overstuffing is an effective precaution that surgeons can take to reduce failures.

Funder

japan agency for medical research and development

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3